PubMed Health⌕ Search

PubMed · 12877709

Threshold measurements: ten rules for good measuring practice.

Abstract

The following rules for professionally measuring thresholds are derived and discussed: RULE 1: Thresholds should be expressed as voltage averaged over pulse duration to get reproducible and comparable results! RULE 2: Pacing threshold measurements with exponentially decaying pulses should not be extended beyond 1.4 ms as that portion of the pulse below rheobase does not contribute to the stimulation effect! RULE 3: Threshold measurements are best carried out with fixed pulse duration and variable voltage! RULE 4: If threshold measurements are carried out in discrete steps, the steps should be chosen such that the relative step size is as equal as possible! RULE 5: Accuracy of threshold measurements is highly increased if the arithmetically averaged value of the last effective and the first ineffective pulse is defined as threshold! RULE 6: To determine strength-duration-curves, a linear regression of the quantity versus pulse duration should be calculated which yields simply the numerical values of the chronaxie and rheobase! RULE 7: To reach representative strength-duration-curves, measurements with at least four pairs of values must be carried out! RULE 8: Measuring defibrillation thresholds, the relative voltage step size should be chosen equally to have equal accuracy for all steps. RULE 9: If the result of a defibrillation threshold investigation does not reach significance, a too large voltage step size could be an explanation! RULE 10: Comparing intraindividually the threshold of two different defibrillation systems or parameter settings, the threshold ratios should be formed and averaged! Obeying these rules guaranties professional threshold measurements expressed as "rheobase" and "chronaxie" even with devices with discrete steps in parameter programming.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Werner Irnich. 2003. Threshold measurements: ten rules for good measuring practice.. https://doi.org/10.1046/j.1460-9592.2003.t01-1-00261.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Medium-term follow-up and modes of failure following epicardial pacemaker implantation in young children.

AIMS: Young children suffering from congenital or post-operative AV-block require life-long pacemaker stimulation. Due to the anatomical prerequisites initially epicardial electrodes are implanted and the generator is placed in the upper abdominal wall. The following study investigated modes of failure leading to reoperation in this group of technically challenging patients. METHODS AND RESULTS: Between October 2000 and May 2005, a total of 21 infants (age 3 days to 5 years) underwent pacemaker implantation using a subxyphoidal incision for newborns (and a partial lower or complete median sternotomy for older children). Nine patients had previous cardiac surgery for complex congenital defects. The remaining 12 young children suffered from congenital AV-Block (CAVB). Twenty-one bipolar epicardial electrodes (Medtronic Capsure epi) were fixed to the right ventricle, 15 had additional implantation of a bipolar atrial lead. The pacemaker generator (Medtronic Kappa 701) was implanted into the right upper abdominal wall. Indications for revision were recorded. No mortality was observed; pacing and sensing parameters remained stable up to a 5-year follow-up. A total of four reoperations occurred. Three of the four revisions were caused by ventricular electrode fracture. At revision, two electrodes were broken at the crossing between the pericardial cavity and the abdominal wall, one bipolar lead at the Y-division into the two tip electrodes. One reoperation was due to a pacemaker recall. All revisions were performed without complications. CONCLUSION: In our institute epicardial pacing in young children was associated with a satisfactory clinical outcome, but also a significant number of failures leading to reoperation, mainly due to electrode fracture caused by the muscular activity of this patient group. Reoperations were performed at a low risk.

Cardiac Pacing, Artificial↗

Spectral pulsed-wave tissue Doppler imaging lateral-to-septal delay fails to predict clinical or echocardiographic outcome after cardiac resynchronization therapy.

AIMS: The current study sought to assess if pre-implantation lateral-to-septal delay (LSD) > or =60 ms assessed by spectral pulsed-wave myocardial tissue Doppler imaging (PW-TDI) could predict successful long-term outcome after cardiac resynchronization therapy (CRT). METHODS AND RESULTS: Sixty patients (72% males, mean age 59 +/- 10 years) who were referred for CRT according to the ACC/ESC guidelines were enrolled in the study. All patients underwent spectral PW-TDI before and 1 year after CRT. Two left ventricular (LV) dyssynchrony time intervals, T(O) and T(P) (time to onset and peak of LV myocardial velocity, respectively), LSD were recorded. Left ventricular dyssynchrony was defined as LSD > or =60 ms. Clinical response was defined as an improvement in >1 NYHA class plus improvement in 6-min walk distance (6MWD) > or =25%, echocardiographic response was defined as a > or =15% reduction in LV end-systolic volume (LV-ESV). One year after CRT, 50 patients (83%) were clinical responders and 47 patients (78%) were echocardiographic responders. Both T(O) and T(P) LV dyssynchrony indices failed to predict echocardiographic CRT outcome. In addition, there were no significant differences between 'synchronous' and 'dyssynchronous' patient populations at baseline or follow-up in either clinical (NYHA class and 6MWD) or echocardiographic (LV ejection fraction, LV end-diastolic, and end-systolic) variables. CONCLUSION: The great majority of patients referred for CRT benefit clinically from it. However, spectral PW-TDI failed to predict CRT outcome. When PW-TDI dyssynchrony was applied for selection of proper CRT patients, up to 80-86% of the patients with synchronous LSD that had proven clinical and echocardiographic benefit from CRT would have been denied CRT.

Cardiac Pacing, Artificial↗