PubMed Health⌕ Search

PubMed · 12892283

Dynamic hip screw removal using a blade plate extraction device.

Abstract

Dynamic hip screw implants are extracted by removing the side plate and compression screws. Occasionally, ingrown bone will prevent easy plate removal. A common solution is to use an osteotome as a levering device; however, the stress riser on the proximal femur caused by this maneuver could result in a catastrophic fracture. A blade plate extraction device fits into the dynamic hip screw side plate and allows relatively atraumatic removal of the implant, preventing the use of excessive force and decreasing the risk of an intraoperative fracture.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wesley P Phipatanakul, J Tracy Watson. 2003. Dynamic hip screw removal using a blade plate extraction device.. https://pubmed.ncbi.nlm.nih.gov/12892283/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stacked plating for metadiaphyseal fractures of the distal radius: a technique report.

Combined injuries of the distal radius and shaft are rare, are usually caused by high energy, and pose a surgical dilemma. Surgical tactics and implants that are routinely used either for isolated fractures of the distal radius or for fractures of the radial shaft are often not applicable for this combined injury. We describe a technique of dual-stacked plating for these metadiaphyseal fractures and its use in two patients.

Bone Plates↗

Plate fixation of olecranon osteotomies.

The management of intra-articular distal humeral fractures remains a difficult surgical problem. Although an olecranon osteotomy provides excellent exposure for management of these fractures, a number of complications can occur after the creation and repair of the osteotomy including nonunion, malunion, hardware failure, and pain secondary to prominent hardware. In an effort to reduce the incidence of these complications, the senior authors now use contoured 3.5 mm reconstruction plates for the fixation of their apex-distal chevron olecranon osteotomies. Two surgeons at a single institution used this technique of exposure on a series of 17 consecutive patients with intra-articular distal humerus fractures between 1996 and 1999. In this series, all osteotomies united. There was one complication related specifically to the osteotomy: one of the screws in the plate penetrated the proximal radioulnar joint, interfering with forearm rotation; a second procedure was required to shorten the screw. Only one of the 17 patients requested plate removal during the 32 month (average) follow-up period. Plate fixation of olecranon osteotomies using a 3.5 mm reconstruction plate provides a construct with predictable healing and few complications. The overall results using this technique are comparable with other reported methods in the literature.

Bone Plates↗