Abstract

OBJECTIVE: To date numerous attempts have been undertaken to conquer the challenging problem of reconstructing long segmental tracheal defects, as yet without lasting success. Recently, employing concepts of tissue engineering in animals, cartilage-like constructs were transplanted in vivo. However, both the feasibility of fabricating tracheal replacements and the use of human tracheal chondrocytes (HTC) for tissue engineering are still under investigation. In this study, we optimized isolation and cultivation techniques for human tracheal cartilage, assessing the feasibility of seeding these cells onto a novel, three-dimensional (3-D) polyester-urethane polymer (DegraPol). METHODS: Human tracheal cartilage was harvested from the trachea of lung donors, digested in 0.3% collagenase II, and the condrocytes serially passaged every 7-9 days. Cells were also cultivated over agar plate during the total 6-8 weeks expansion phase. Thereafter, chondrocytes were seeded onto DegraPol (pore sizes 150-200 microm) with a seeding density of 2.4 x 10(7)/ml, and chondrocyte-polymer constructs maintained during in vitro static culture. RESULTS: HTC displayed stable proliferation kinetics in monolayer culture with positive expression of collagen type II. Following polymer seeding, both cellular proliferation and extracellular matrix (ECM) production, as measured by MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) and glycosaminoglycan assays, continued over extended culture. Active growth of HTC on DegraPol was further demonstrated by Alcian blue staining, with the histomorphological appearance of the construct resembling that of native cartilage. Scanning electron microscopy showed chondrocyte growth and ECM synthesis both on the surface and inside the porous scaffold, with a dense cell layer on the surface of the scaffold and a lower cell distribution in the scaffold's interior. CONCLUSIONS: The harvested chondrocytes from human trachea cartilage expand well in vitro and possess the ability to form new cartilage-like tissue when seeded onto DegraPol matrix. However, improved culture conditions are needed to permit cellular growth throughout cell-polymer constructs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lin Yang, Stephan Korom, Manfred Welti, Simon P Hoerstrup, Gregor Zünd, Florain J Jung, Peter Neuenschwander, Walter Weder. 2003. Tissue engineered cartilage generated from human trachea using DegraPol scaffold.. https://doi.org/10.1016/s1010-7940(03)00263-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Plug migration and cement mantle assessment in total hip replacement.

We reviewed a series of consecutive total hip replacements with cemented femoral components. Modern cementing techniques were followed in all cases, but two different medullary plugs were used-one was polyethylene and the other bioabsorbable gelatin. Cement mantle quality and plug migration were assessed by three different observers (X, Y, and Z); their findings did not agree. This was particularly evident when the cement mantles were assessed. There was a better cement mantle grading and less distal migration with polyethylene plugs, although there was no significant statistical difference between the two groups.

Absorbable Implants↗

First evidence that bone marrow cells contribute to the construction of tissue-engineered vascular autografts in vivo.

BACKGROUND: Materials commonly used to repair complex cardiac defects lack growth potential and have other unwanted side effects. We designed and tested a bone marrow cell (BMC)-seeded biodegradable scaffold that avoids these problems. METHODS AND RESULTS: To demonstrate the contribution of the BMCs to histogenesis, we labeled them with green fluorescence, seeded them onto scaffolds, and implanted them in the inferior vena cava of dogs. The implanted grafts were analyzed immunohistochemically at 3 hours and subsequently at 2, 4, and 8 weeks after implantation using antibodies against endothelial cell lineage markers, endothelium, and smooth muscle cells. There was no stenosis or obstruction caused by the tissue-engineered vascular autografts (TEVAs) implanted into the dogs. Immunohistochemically, the seeded BMCs expressing endothelial cell lineage markers, such as CD34, CD31, Flk-1, and Tie-2, adhered to the scaffold. This was followed by proliferation and differentiation, resulting in expression of endothelial cells markers, such as CD146, factor VIII, and CD31, and smooth muscle cell markers, such as alpha-smooth muscle cell actin, SMemb, SM1, and SM2. Vascular endothelial growth factor and angiopoietin-1 were also produced by cells in TEVAs. CONCLUSIONS: These results provide direct evidence that the use of BMCs enables the establishment of TEVAs. These TEVAs are useful for cardiovascular surgery in humans and especially in children, who require biocompatible materials with growth potential, which might reduce the instance of complications caused by incompatible materials and lead to a reduced likelihood of further surgery.

Absorbable Implants↗

Long-term study of high-strength hydroxyapatite/poly(L-lactide) composite rods for the internal fixation of bone fractures: a 2-4-year follow-up study in rabbits.

Biodegradation of hydroxyapatite (HA)/poly(L-lactide)(PLLA) composite bone implant rods was studied with the use of two types of HA particles as reinforcing fillers: uncalcined HA (u-HA) or calcined HA (c-HA). Composite rods of u-HA/PLLA and c-HA/PLLA containing 30 or 40% (w/w) HA were implanted in the distal femur of 21 rabbits, and specimens were examined by light microscopy, scanning-electron microscopy (SEM), and transmission-electron microscopy (TEM) 2-4 years later. For u-HA/PLLA, trabecular bone bonding directly onto the rod was maintained for up to 2 years. By 3 years, surface collapse had begun, and the implants were shrinking. By 4 years, they had shrunk further, with complete bone encapsulation. The u-HA particles were small and needle shaped in the peripheries, and TEM confirmed their resorption. The cross-sectional area after 4 years decreased by 23.3+/-8.4%. The mean ratio of bony ingrowth to the initial cross-sectional area around the shrunken rods was 6.7+/-1.3 %. The viscosity molecular weight of PLLA reduced from 2 x 10(5) to less than 1 x 10(3). Thus, most of the PLLA had released from the rods. The c-HA/PLLA implants also showed good osteoconductivity, but shrinkage and infiltration of histiocytes were less. No osteolytic or osteoarthritic changes were found.

Absorbable Implants↗