PubMed Health⌕ Search

PubMed · 12929972

Protein separation by monolithic capillary electrochromatography.

Abstract

This work presents the separation of model proteins by capillary electrochromatography involving a monolithic stationary phase with C4 functionality. The monolith was fabricated in UV-transparent capillaries by employing a slight modification of a recently published photopolymerization procedure. With the number of theoretical plates per column ranging between 11000 and 33000, the separation efficiency proved to be lower than capillary zone electrophoresis where plate numbers ranged between 18000 and 66000. However, higher resolution was obtained due to the additional chromatographic separation mechanism. Inter- and intra-column reproducibility were evaluated, the latter could be significantly improved when using a rinsing procedure that contained 0.05% sodium dodecylsulfate in the mobile phase. Plate heights became nearly independent of mobile phase velocities higher than 0.5 mm/s indicating that high velocities can be applied without sacrificing efficiency. Furthermore, peak heights showed a dependence on injection times. For proteins, an increase in capacity factors was found when increasing the percentage of organic solvent in the mobile phase.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dirk Bandilla, Cameron D Skinner. 2003-07-04. Protein separation by monolithic capillary electrochromatography.. https://doi.org/10.1016/s0021-9673(03)00450-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Recent progress in the use of ionic polymers as pseudostationary phases for EKC.

This review concerns the introduction, characterization, and application of polymeric pseudostationary phases (PSPs) for EKC since 2004. Achiral and chiral polymers and separations are reviewed, as is the application of polymeric PSPs for the combination of EKC with mass spectrometric detection.

Chromatography, Micellar Electrokinetic Capillary↗

MEKC: an update focusing on practical aspects.

This paper reviews recent methodological and instrumental advances in MEKC. Improvements in sensitivity arising from the use of on-line sample concentration (sweeping, stacking, and combination of both protocols) and derivatization (in-capillary reactions and coupling with flow-injection systems) and improvements in resolution obtained by changing the composition of the BGE (e.g., with organic modifiers, ionic liquids, nonionic and zwitterionic surfactants, mixed micelles, and vesicles) or using coated capillaries are discussed in detail. In addition, MS and LIF spectroscopy are examined in relation to their advantages and restrictions as applied to MEKC analysis. Some thoughts on potential future directions are also expressed.

Chromatography, Micellar Electrokinetic Capillary↗

Comparison of migration models for acidic solutes in micellar electrokinetic chromatography.

The validity of two models that explain the migration of ionisable solutes in micellar electrokinetic chromatography (MEKC), mobility model and retention factor model, has been tested. For this purpose, the mobility (mu) and retention factor (k) of a set of 10 phenolic compounds with different hydrophobicity and pKa values have been determined for several sodium dodecyl sulphate (SDS) concentrations and pH values, and fitted to the models. Results show that in general the retention factor model explains better the retention of ionisable solutes, although for hydrophilic compounds at low SDS concentration, mobility model can give better fits. The different drawbacks pointed out by several authors in relation to both models have been checked, and a deep evaluation of each one has been done. As a result we have observed that, while in the retention factor model the variation of k with pH and [SDS] always follows the same trend, the variation of mu with these variables mainly depends on the value of the binding constant of the neutral form of the solutes to the micelles, KHA(m), which plays a critical role in the fit of the mobility model. Also we provide rules and advices to set up the experimental conditions to apply each model to a particular solute.

Chromatography, Micellar Electrokinetic Capillary↗