A disc-type magneto-rheologic fluid damper.

Abstract

A disc-type magneto-rheological fluid damper operating in shear mode is proposed in this paper, which is based on the special characteristics of the magneto-rheological (MR) fluid with rapid, reversible and dramatic change in its rheological properties by the application of an external magnetic field. The magnetic field of the disc-type MR fluid damper is analysed by the finite element method; the controllability of the disc-type MR fluid damper on the dynamic behaviour of a rotor system; and the effectiveness of the disc-type MR fluid damper in controlling the vibration of a rotor system, are studied in a flexible rotor system with an over-hung disc. It is shown that the magnetic flux density of the disc-type MR fluid damper in the working areas can significantly change with the applied current in the coil; and that the dynamic behavior of the disc-type MR fluid damper can be varied by the application of an external magnetic field produced by a low voltage electromagnetic coil. The disc-type MR fluid damper can significantly change the dynamic characteristics of a rotor system, provided that the location of the disk-type MR fluid damper is carefully chosen. The disc-type MR fluid damper is a new actuator with good dynamic characteristics for rotating machinery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chang-sheng Zhu. A disc-type magneto-rheologic fluid damper.. https://doi.org/10.1631/jzus.2003.0514

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Probing motions between equivalent RNA domains using magnetic field induced residual dipolar couplings: accounting for correlations between motions and alignment.

Approaches developed thus for extracting structural and dynamical information from RDCs have rested on the assumption that motions do not affect molecular alignment. However, it is well established that molecular alignment in ordered media is dependent on conformation, and slowly interconverting conformational substates may exhibit different alignment properties. Neglecting these correlation effects can lead to aberrations in the structural and dynamical analysis of RDCs and diminish the utility of RDCs in probing motions between domains having similar alignment propensities. Here, we introduce a new approach based on measurement of magnetic field induced residual dipolar couplings in nucleic acids which can explicitly take into account such correlations and demonstrate measurements of motions between two "magnetically equivalent" domains in the transactivation response element (TAR) RNA.

Magnetics↗

A subfemtotesla multichannel atomic magnetometer.

The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.

Magnetics↗