PubMed Health⌕ Search

PubMed · 12964729

A PCR-based anthrax detector.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Katie Cottingham. 2003-07-01. A PCR-based anthrax detector.. https://doi.org/10.1021/ac031364n

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Identification of sporulation genes in Bacillus anthracis highlights similarities and significant differences with Bacillus subtilis.

The molecular basis of endospore formation in the model gram-positive bacterium Bacillus subtilis has been investigated for over half a century. Here, using high throughput and classical genetic approaches, we performed a comparative analysis of sporulation in the human pathogen Bacillus anthracis. A transposon-sequencing screen identified >150 genes required for B. anthracis sporulation. As anticipated, many of the genes that are critical for sporulation in B. subtilis were also required for B. anthracis sporulation. However, we identified >50 genes that are important for sporulation in B. anthracis but not in B. subtilis, and 22 B. anthracis sporulation genes that are absent from the B. subtilis genome. To validate the hits from our screen, we generated an ordered transposon-mutant library using Knockout Sudoku. Cytological analysis of a subset of the canonical sporulation-defective mutants revealed similar but not identical phenotypes in the pathogen compared to the model. We investigated several of the newly identified sporulation genes, with an in-depth analysis of one, ORF 04167, renamed ipdA. Sporulating cells lacking ipdA are blocked in the morphological process of engulfment, generating septal bulges. An AlphaFold-Multimer screen and a classical genetic enrichment revealed that IpdA is a secreted inhibitor of the polysaccharide deacetylase PdaN. Our data support a model in which induction of IpdA at the onset of sporulation inhibits deacetylation of the cell wall peptidoglycan (PG), enabling the sporulation-specific PG hydrolases to catalyze engulfment. Altogether, our studies reveal that B. subtilis is an excellent model for endospore formation in B. anthracis, while underscoring the importance of direct analysis in B. anthracis. The suite of tools that we have generated will catalyze the molecular dissection of sporulation and other cell biological processes in this important human pathogen.

Bacillus anthracis↗

A handheld real time thermal cycler for bacterial pathogen detection.

The handheld advanced nucleic acid analyzer (HANAA) is a portable real time thermal cycler unit that weighs under 1 kg and uses silicon and platinum-based thermalcycler units to conduct rapid heating and cooling of plastic reaction tubes. Two light emitting diodes (LED) provide greater than 1 mW of electrical power at wavelengths of 490 nm (blue) and 525 nm (green), allowing detection of the dyes FAM and JOE/TAMRA. Results are displayed in real time as bar graphs, and up to three, 4-sample assays can be run on the charge of the 12 V portable battery pack. The HANAA was evaluated for detection of defined Escherichia coli strains, and wild-type colonies isolated from stream water, using PCR for the lac Z and Tir genes. PCR reactions using SYBR Green dye allowed detection of E. coli ATCC 11775 and E. coli O157:H7 cells in under 30 min of assay time; however, background fluorescence associated with dye binding to nonspecific PCR products was present. DNA extracted from three isolates of Bacillus anthracis Ames, linked to a bioterrorism incident in Washington DC in October 2001, were also successfully tested on the HANAA using primers for the vrrA and capA genes. Positive results were observed at 32 and 22 min of assay time, respectively. A TaqMan probe specific to the aroQ gene of Erwinia herbicola was tested on the HANAA and when 500 cells were used as template, positive results were observed after only 7 min of assay time. Background fluorescence associated with the use of the probe was negligible. The HANAA is unique in offering real time PCR in a handheld format suitable for field use; a commercial version of the instrument, offering six reaction chambers, is available as of Fall 2002.

Bacillus anthracis↗