PubMed Health⌕ Search

PubMed · 13076026

[Acetyl-digitoxin].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A STOLL, W KREIS. 1953-03-14. [Acetyl-digitoxin].. https://pubmed.ncbi.nlm.nih.gov/13076026/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Characterisation of the binding of digitoxin and acetyldigitoxin to human serum albumin by high-performance affinity chromatography.

Zonal elution and high-performance affinity chromatography were used to examine interactions of the drugs digitoxin and acetyldigitoxin with the protein human serum albumin (HSA). This was done by injecting small amounts of digitoxin and acetyldigitoxin onto an immobilized HSA column in the presence of mobile phases that contained various concentrations of digitoxin, acetyldigitoxin or other solutes as competing agents. A fixed concentration of beta-cyclodextrin was also present in the mobile phase as a solubilising agent. It was found that digitoxin and acetyldigitoxin each had strong interactions at a single common binding site on HSA, but with slightly different equilibrium constants for this region. Neither compound showed any competition with warfarin or L-tryptophan, which were used as probes for binding at the warfarin-azapropazone and indole-benzodiazepine sites of HSA. These results confirmed the presence of a separate binding region on HSA for digitoxin-related compounds.

Acetyldigitoxins↗

Separation of cardiac glycosides by micellar electrokinetic chromatography and microemulsion electrokinetic chromatography.

The interest of micellar electrokinetic chromatography (MEKC) and microemulsion electrokinetic chromatography (MEEKC) for the resolution of four cardiac glycosides is demonstrated. First, the influence of some parameters on the resolution of the solutes in MEKC such as the concentration of the surfactant, pH, addition of organic modifiers and urea is discussed. Then, results are compared with those obtained in MEEKC using different microemulsion compositions. Results indicate that MEEKC possesses several advantages over MEKC for the separation of relatively hydrophobic compounds such as digitalic compounds. First, microemulsions allow a better manipulation of the migration time window and of the retention of the solutes. Moreover, efficiency is improved with shorter analysis time.

Acetyldigitoxins↗

High-performance liquid chromatography-ionspray mass spectrometry for the specific determination of digoxin and some related cardiac glycosides in human plasma.

An original method based upon high-performance liquid chromatography coupled to ionspray mass spectrometry (HPLC-ISP-MS) has been developed for the identification and quantification in plasma of several cardiac glycosides, namely digoxin, digitoxin, lanatoside C and acetyldigitoxin. After single-step liquid-liquid extraction by chloroform-2-propanol (95:5, v/v) at pH 9.5 using oleandrin as an internal standard, solutes are separated on a 4 microm NovaPak C18 (Waters) column (150x2.0 mm, I.D.), using a gradient of acetonitrile-2 mM NH4COOH, pH 3 buffer (flow-rate 200 microl/min, post-column split 1:3). Detection is done by a Perkin-Elmer Sciex API-100 mass analyzer equipped with an ISP interface. In most instances the major ion observed is not [M+H]+ as expected, but [M+NH4]+. The mean retention times (min) are: lanatoside C, 5.74; digoxin, 6.00; digitoxin, 8.08, oleandrin, 8.30, acetyldigitoxin, 8.66 and 9.01 (isomers alpha and beta, respectively). The lower limits of detection in single ion monitoring mode range from 0.15 ng/ml (alpha- and beta-acetyldigitoxin) to 0.60 ng/ml (lanatoside C), making the method less sensitive than radioimmunoassay, whereas it is much more specific.

Acetyldigitoxins↗