PubMed Health⌕ Search

PubMed · 13109778

On microelectrodes for plotting currents in nervous tissue.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B HOWLAND, J Y LETTVIN, W S McCULLOCH, W PITTS, P D WALL. 1953. On microelectrodes for plotting currents in nervous tissue.. https://pubmed.ncbi.nlm.nih.gov/13109778/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Polymer microspray with an integrated thick-film microelectrode.

A microfabrication process leading to a sheathless electrospray interface for mass spectrometry analysis is described. Photoablation is performed on a polymer substrate, allowing the integration of a thick-film conductive track in a sealed microchannel. High voltage is supplied close to the outlet, through an embedded microelectrode. The microspray is generated directly from the edge of the substrate without any tip addition. The flexibility of this technology provides a wide range of dimensions for the probe and the microelectrode design, including location, shape, and conductive material used. Thanks to the thick-film microelectrode and the hydrophobicity of the polymer, which avoids solution spreading at the outlet, the device has been found to be an efficient ionization source providing a stable MS signal through time. Moreover, the same device can be used several times without failure. The performance of the microspray has been studied in simple infusion mode for proteins and reserpine MS analyses. The detection limit of reserpine was found to be at the picomolar level in full-scan MS mode. It implies also that approximately 500 zmol was read consumed during 3 min of infusion. A dynamic range from pico- to millimolar level is also underlined.

Microelectrodes↗

A new design of carbon fiber microelectrode for in vivo voltammetry using fused silica.

Voltammetric probes were constructed from stainless steel and fused silica tubing sheathing carbon fibers. Electrochemical tests were carried out to compare these electrodes with commercially available glass-sealed IVEC-5 electrodes. Electrodes of both types displayed a similar declining baseline and calculated coefficients of stabilization (tangent of baseline during a stable period). There were no significant differences in sensitivity between the two designs of electrodes to norepinephrine (NE) and dopamine (DA). All tested electrodes showed linear current responses to increasing concentrations of NE and DA. Fused silica (FS type) electrodes are suitable for electrochemical measurements (in vivo voltammetry) and display characteristics similar to those of commercially available IVEC-5 glass-sealed carbon fiber microelectrodes. Manufacture of FS type electrodes in a biochemical laboratory is easy and does not require any special equipment (such as a micropipette puller) or glass-handling skills. An additional fused silica tube can be glued to the electrode for microinjections. The electrodes are very robust, easy to handle and can be mounted on the arms of standard stereotaxic instruments. The electrodes can be made long enough to reach the deepest parts of brain of large animals.

Microelectrodes↗