PubMed Health⌕ Search

PubMed · 13158002

Creatinine tolerance test as a renal function test.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E NORBYE. 1954. Creatinine tolerance test as a renal function test.. https://doi.org/10.1111/j.1651-2227.1954.tb04008.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Increasing the efficiency of in-capillary electrophoretically mediated microanalysis reactions via rapid polarity switching.

We report herein a new approach to enhance the sensitivity or speed of CE-based methods that involve in-line reactions. Rapid polarity switching (RPS) is used as a novel means for in-line mixing of two reactant solutions via rapid (1-5 s) and sequential switching of the applied potential field. By employing the RPS approach with a model chemical reaction, that between creatinine and alkaline picrate, significant enhancement in sensitivity (or a decrease in analysis time) is realized. Both increased convection and electrophoretic stacking of the ionic reagent appear to contribute to the rise in apparent reaction rate. When coupled with in-line chemistry of the Jaffe method for creatinine, the RPS methodology allows for 3-fold faster determination of creatinine in the concentration range needed for the analysis of clinical blood serum specimens. The new approach also allows the analysis to be performed without the need for the cumbersome and problematic enhanced sensitivity cell.

Creatinine↗

Formation of a mutagenic heterocyclic aromatic amine from creatinine in urine of meat eaters and vegetarians.

Liquid chromatography electrospray ionization mass spectrometry (MS) with a triple quadrupole MS was used to identify known and novel heterocyclic aromatic amines (HAAs) in human urine. The identities of 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (8-MeIQx) and 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) were confirmed by their product ion spectra. The constant neutral loss scan mode was employed to probe for other analytes in urine that display the transition [M+H]+-->[M+H-CH3*]+*, which is common to HAAs containing an N-methylimidazo moiety, and led to the detection of a previously unreported isomer of 8-MeIQx [Holland, R., et al. (2004) Chem. Res. Toxicol. 17, 1121-1136]. We now report the identification of another novel HAA, 2-amino-1-methylimidazo[4,5-b]quinoline (IQ[4,5-b]), an isomer of the powerful animal carcinogen 2-amino-3-methylimidazo[4,5-f]quinoline (IQ). The amounts of IQ[4,5-b] measured in the urine of human volunteers who consumed grilled beef ranged from 15 to 135% of the ingested dose, while the amounts of 8-MeIQx and PhIP excreted in urine were on average <2% of the ingested dose. Base treatment of urine at 70 degrees C increased the concentrations of 8-MeIQx and PhIP by as much as 6-fold, indicating the presence of phase II conjugates; however, the amount of IQ[4,5-b] increased by more than 100-fold. IQ[4,5-b] was also detected in the urine of vegetarians following base hydrolysis. The formation of IQ[4,5-b], but not IQ, 8-MeIQx, or PhIP, also occurred in urine incubated at 37 degrees C. Creatinine and 2-aminobenzaldehyde are likely precursors of IQ[4,5-b]. The detection of IQ[4,5-b] in the urine of both meat eaters and vegetarians suggests that this HAA may be present in nonmeat staples or that IQ[4,5-b] formation may occur endogenously within the urinary bladder or other biological fluids.

Creatinine↗