PubMed Health⌕ Search

PubMed · 13158124

Pulmonary circulation time; a densometric study.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B NORDENSTROM. 1954. Pulmonary circulation time; a densometric study.. https://doi.org/10.3109/00016925409175848

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A dose-response curve for the negative bias pressure of an intrathoracic pressure regulator during CPR.

An intrathoracic pressure regulator (ITPR) is a device that can be added to the external end of a tracheal tube to create controlled negative airway pressure between positive pressure ventilations. The resulting downward bias of the airway pressure baseline promotes increased venous return and enhanced circulation during CPR and also during hypovolemic shock. In the present study, we exercised a mathematical model of the human cardiopulmonary system, including airways, lungs, a four chambered heart, great vessels, peripheral vascular beds, and the biomechanics of chest compression and recoil, to determine the relationship between systemic perfusion pressure during CPR and the value of baseline negative airway pressure in an ITPR. Perfusion pressure increases approximately 50% as baseline airway pressure falls from zero to -10 cm H2O. Thereafter perfusion pressure plateaus. Negative bias pressures exceeding -10 cm H2O are not needed in ITPR-CPR.

Blood Circulation↗

Analytical identification of ideal pulmonary-systemic flow balance in patients with bidirectional cavopulmonary shunt and univentricular circulation: oxygen delivery or tissue oxygenation?

BACKGROUND: In the present study, we extended previous mathematical modeling work on patients with bidirectional cavopulmonary ("bidirectional Glenn") anastomosis to assess the potential utility of several descriptors of oxygen status. We set out to determine which of these descriptors best represents the overall tissue oxygenation. We also introduce a new descriptor, SO2min, defined as the lower of the superior and inferior vena cava oxygen saturations. METHODS AND RESULTS: The application of differential calculus to a model of oxygen physiology of patients with bidirectional Glenn allowed simultaneous assessment of all possible distributions of blood flow and metabolic rate between upper and lower body, across all cardiac outputs, total metabolic rates, and oxygen-carrying capacities. When total cardiac output is fixed, although it may intuitively seem best to distribute flow to maximize oxygen delivery (total, upper body, or lower body), we found that for each variable, there are situations in which its maximization seriously deprives flow to the upper or lower circulation. In contrast, maximizing SO2min always gives physiologically sensible results. If the majority of metabolism is in the upper body (typical of infancy), then oxygenation is optimized when flow distribution matches metabolic distribution. In contrast, if the majority of metabolism is in the lower body (typical of older children and during exercise), oxygenation is optimal when flows are equal. CONCLUSIONS: In patients with bidirectional cavopulmonary anastomosis, because there is a tradeoff between flow distribution and saturation, it is unwise to concentrate on maximizing oxygen delivery. Maximizing systemic venous saturations (especially SO2min) is conceptually different and physiologically preferable for tissue oxygenation.

Blood Circulation↗