PubMed Health⌕ Search

PubMed · 13608923

Placentography.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H A NOVELL, J H FERGUSON. 1958. Placentography.. https://doi.org/10.1097/00003081-195809000-00011

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Emergent stenting to treat patients with carotid artery dissection: clinically and radiologically directed therapeutic decision making.

BACKGROUND AND PURPOSE: Carotid artery dissection (CAD) is a common cause of stroke in young patients. Clots formed at the low-flow zone in the false arterial lumen may give rise to distal emboli, and the mural hematoma may eventually occlude the artery. Anticoagulation is currently the accepted treatment, but it is unknown which patients will improve spontaneously, which will respond to anticoagulation, and which will have an exacerbation of ischemic symptoms despite therapy. Endovascular treatment of CAD may be an attractive alternative to anticoagulation, and methods of identifying patients who stand to benefit from such therapy need to be established. METHODS: We present here 3 cases of spontaneous symptomatic CAD in which endovascular stenting procedures were performed on the basis of a paradigm aimed at identifying potentially salvageable but at-risk brain tissue by combining clinical with MRI (diffusion and perfusion) and angiographic data. RESULTS: Diffusion-perfusion MRI mismatches and/or evidence of cerebral ischemia on angiographic parenchymography were identified in all patients. They did not respond to anticoagulation, were therefore treated with endovascular stents, and had excellent outcomes. CONCLUSIONS: Endovascular stent placement may be an immediate, effective, and safe method of restoring vessel lumen integrity. It may be considered for selected patients who are clinically symptomatic despite anticoagulant treatment and in whom neuroimaging methods suggest that the neurological signs originate from a viable, hypoperfused, ischemic penumbra.

Angiography↗

3-dimensional colour power angiography for staging human placental development.

Maldevelopment of placental villous trees and their blood vessels results in impaired fetal growth, which can greatly compromise fetal, neonatal, childhood, and adulthood health. There are no means of directly assessing such maldevelopment. We have applied a new technique of imaging (colour power angiography [CPA]) with 3-dimensional reconstruction to assess directly villous development in human pregnancy in vivo in 20 uncomplicated pregnancies from 13 to 38 weeks' gestation. The chronology of villous trees was much the same in 3-dimensional CPA, scanning electron micrography, and classical histology from controls matched by age. This approach provides a unique opportunity to examine normal placental development directly, and should provide the bases for real-time investigation of placental pathology and a robust method for diagnosis and surveillance during pregnancy.

Angiography↗

Use of a self-expanding occluding stent for nonsurgical closure of patent ductus arteriosus in dogs.

OBJECTIVE: To evaluate the clinical application of a catheter-delivered, self-expanding occluding stent for closure of patent ductus arteriosus (PDA) in dogs. DESIGN: Prospective study. ANIMALS: 23 client-owned dogs weighing at least 3 kg (6.6 lb). PROCEDURE: Dogs were evaluated by physical examination, electrocardiography, thoracic radiography, and 2-dimensional, M-mode, spectral and color-flow Doppler echocardiography to confirm the diagnosis and obtain baseline measures. Shunt severity and ductal size and anatomy were established by means of angiography. With fluoroscopic guidance, the occluding stent, attached to a delivery cable, was maneuvered though the right side of the heart into the ductus via a prepositioned introducer sheath. After angiographic verification of appropriate stent placement, the delivery cable was detached, and the introducer sheath was withdrawn. Closure of the PDA was evaluated by means of angiography 15 minutes after stent deployment and by echocardiography 1 and 3 months after the procedure. RESULTS: There were no operative deaths. There were 2 deployment failures, both attributable to avoidable operator errors. Angiography performed after stent deployment indicated PDA closure in 13 of 20 (65%) dogs. There were 2 postoperative deaths in dogs with heart failure; both deaths were thought to be unrelated to use of the occluding stent. Complete PDA closure, determined by Doppler color-flow echocardiography, was evident in 17 of 19 dogs within 3 months and in 1 additional dog within 1 year of stent deployment, resulting in closure in 18 of 19 dogs completing the study protocol. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that a catheter-delivered occluding stent can be used successfully to close PDAs in dogs.

Angiography↗