PubMed Health⌕ Search

PubMed · 13649685

A simple device for calibrating test tubes.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D S LINDBERG, L J BIELINSKI, F J WENZEL. A simple device for calibrating test tubes.. https://pubmed.ncbi.nlm.nih.gov/13649685/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development and validation of a method for the quantitation of Delta9tetrahydrocannabinol in oral fluid by liquid chromatography electrospray-mass-spectrometry.

Analysis of Delta(9)tetrahydrocannabinol (Delta(9)THC) and its metabolites in biological samples is of great relevance for forensic purposes. In the case of oral fluid (OF), the analysis should determine Delta(9)THC, whereas in urine, it detects the inactive metabolite tetrahydrocannabinol carboxylic acid (THC-COOH). Most laboratories analyze Delta(9)THC in such samples using GC-MS methods, but these procedures are time-consuming and involve unavoidable previous extraction and derivatization. No data is yet available on the application of liquid chromatography-mass-spectrometry to detect Delta(9)THC in oral fluid. We report a validation method in which the Delta(9)THC is isolated from oral fluid by a simple liquid-liquid extraction with hexane and subsequently analyzed by liquid chromatography-mass-spectrometry. The method here reported for the determination of Delta(9)THC in oral fluid only requires 200 microl of sample and achieves limits of detection of 2 ng/ml, and has been used to analyze oral fluid samples collected from current drug users.

Calibration↗

Quantitative determination of MK-0767, a dual alpha/gamma peroxisome proliferator-activated receptor (PPAR) agonist, in human plasma by liquid chromatography-tandem mass spectrometry.

5-[2,4-Dioxothiazolidin-5-yl)methyl]-2-methoxy-N-[[(4-trifluoromethyl)-phenyl]methyl]benzamide (I, MK-0767 or KRP-297, Fig. 1), is a dual alpha/gamma peroxisome proliferator-activated receptor (PPAR) agonist. A LC-MS/MS method for the determination of I in human plasma has been successfully developed, validated and applied to clinical programs. The analyte and internal standard (II) are extracted from 0.05 mL plasma via solid phase extraction (SPE). HPLC is used for the separation of I and II from possible co-extracted endogenous and other compounds. Detection is by MS/MS in multiple reaction monitoring (MRM) mode using a TurboIonSpray probe. The whole sample preparation is automated by using a Packard Multiprobe liquid handling system. The linear range is 4-2000 ng/mL in plasma. Recoveries were 71.1% and 69.4% for I and II, respectively. The method exhibited good linearity, reproducibility and sensitivity, selectivity and robustness when used for the analysis of clinical samples.

Calibration↗

Rapid determination of loratadine in small volume plasma samples by high-performance liquid chromatography with fluorescence detection.

A simple and rapid high-performance liquid chromatographic method with fluorescence detection was developed for the determination of loratadine in small volume plasma samples. Liquid-liquid extraction of loratadine and diazepam (as internal standard) from plasma samples was performed with n-butyl alcohol/n-hexane (2:98, v/v) in alkaline condition followed by back-extraction into diluted perchloric acid. Chromatography was carried out using a C8 column (250 x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-20 mM sodium dihydrogen phosphate-triethylamine (43:57:0.02, v/v), pH 2.4. Analyses were run at a flow-rate of 1.0 ml/min at room temperature. The method was specific and sensitive with a quantitation limit of 0.62 ng/ml and a detection limit of 0.2 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery of loratadine from plasma was 84%, while the intra-and inter-day coefficient of variation and percent error values of the assay method were all less than 9.7%. Linearity was assessed in the range of 0.62-20 ng/ml in plasma with a correlation coefficient of greater than 0.999. The method has been used to analyze several hundred human plasma samples for bioavailability studies.

Calibration↗