PubMed Health⌕ Search

PubMed · 13655173

Hereditary dentinogenesis imperfecta.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O N JOHNSON, A P CHAUDHRY, R J GORLIN, D F MITCHELL, W L BARTHOLDI. 1959. Hereditary dentinogenesis imperfecta.. https://doi.org/10.1016/s0022-3476(59)80146-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The use of optical parametric oscillator for harmonic generation and two-photon UV fluorescence microscopy.

Ultrafast lasers have found increasing use in scanning optical microscopy due to their very high peak power in generating multiphoton excitations. A mode-locked Ti:sapphire laser is often employed for such purposes. Together with a synchronously pumped optical parametric oscillator (OPO), the spectral range available can be extended to 1,050-1,300 nm. This broader range available greatly facilitates the excitation of second harmonic generation (SHG) and third harmonic generation (THG) due to better satisfaction of phase matching condition that is achieved with a longer excitation wavelength. Dental sections are then investigated with the contrasts from harmonic generation. In addition, through intra-cavity doubling wavelengths from 525-650 nm are made available for effective two-photon (2-p) excitation with the equivalent photon energy in the UVB range (290-320 nm) and beyond. This new capacity allows UV (auto-) fluorescence excitation and imaging, for example, from some amino acids, such as tyrosine, tryptophan, and glycine.

Dentin↗

The effects of tubule orientation on fatigue crack growth in dentin.

The fracture of restored teeth is a significant obstacle to lifelong oral health. Recent studies suggest that fatigue cracks originate at flaws introduced during cavity preparation and that fatigue crack growth is a principle cause of restored tooth fractures. In this study, the rate of fatigue crack growth in bovine dentin was estimated under mode I cyclic loading. Double cantilever beam (DCB) specimens were obtained from bovine molars and subjected to high cycle fatigue loading (10(5) < N < 10(6)). The fatigue crack growth rates were measured and used to estimate the crack growth exponent and coefficient according to the Paris Law. The average fatigue crack growth exponent was 4.7 +/- 0.6 for crack growth parallel to the dentin tubules, which was significantly larger than 4.3 +/- 0.5 for crack growth perpendicular to the tubules (t-test, CI > 80%). Although the crack growth rates varied considerably, there was no significant dependence on tubule orientation or tubule density. However, specific features of the fracture surfaces and tendencies for crack curving away from the tubules suggested preferential fatigue crack growth perpendicular to the dentin tubules. Results from this study are being used to guide an experimental investigation of fatigue crack growth in human dentin.

Dentin↗

Microhardness of superficial and deep sound human dentin.

Our purpose in this study was to determine the microhardness of superficial and deep dentin by means of two indentation methods (Knoop and Vickers) under two different applied loads. Twelve dentin discs approximately 2-mm thick were obtained from both superficial and deep dentin by transversally sectioning the crowns of sound, extracted human third molars with a diamond blade under water irrigation. Dentin surfaces were sequentially polished, and indentations (n = 20 per surface) were performed with either Vickers indentor at loads of 300 and 500 g, respectively, or Knoop indentor at loads of 50 and 100 g, respectively. Average Vickers hardness number (VHN) and Knoop hardness number (KHN) were calculated and treated with two-way analysis of variance (ANOVA) and Student's t test. Microhardness of dentin was not influenced by the different loads applied for both indentation methods. Knoop hardness was significantly higher for superficial than for deep dentin (p < 0.05). Conversely, Vickers hardness was not significantly different for both substrates (p > 0.05). Differences in dentin hardness as a function of depth exist, but they might not be relevant, and no alteration of the distribution of stresses along the adhesive interface is expected.

Dentin↗