Abstract

Taking advantage of the long 13C T1 values generally encountered in solids, selective saturation and inversion of more than one resonance in 13C CP/MAS experiments can be achieved by sequentially applying several DANTE pulse sequences centered at different transmitter frequency offsets. A new selective saturation pulse sequence is introduced composed of a series of 90 degrees DANTE sequences separated by interrupted decoupling periods during which the selected resonance is destroyed. Applications of this method, including the simplification of the measurement of the principal values of the 13C chemical shift tensor under slow MAS conditions, are described. The determination of the aromaticity of coal using a relatively slow MAS rate is also described.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Z Hu, R J Pugmire, A M Orendt, D M Grant, C Ye. 1992. Selective saturation and inversion of multiple resonances in high-resolution solid-state 13C experiments using slow spinning CP/MAS and tailored DANTE pulse sequences.. https://doi.org/10.1016/s0926-2040(10)80003-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of haloanisols in white wine by immunosorbent solid-phase extraction followed by enzyme-linked immunosorbent assay.

A high through-put screening immunochemical method to control the presence of 2,4,6-trichloroanisol (TCA) and 2,4,6-tribromoanisol (TBA), the main agents responsible for the musty odor in wine samples, has been developed. The method involves a selective (antibody-antigen) solid-phase extraction (SPE), followed by enzyme-linked immunosorbent assay (ELISA) analysis. The sample preparation method established uses for immunosorbents (ISs) prepared by covalently coupling antibodies developed for TCA on a sepharose support. At present, about 200-400 ng L-1 of TBA and TCA can be detected in white wine samples by the IS-SPE-ELISA method described here without any preconcentration step. Simultaneous analyses of many samples are possible with this method. Related chloroanisoles (2,3- and 2,6-dichloroanisols and 2,3,4,5-tetrachloroanisol) and chlorophenols (2,3,4,6-tetrachlorophenol and pentachlorophenol) usually present in contaminated wine samples are also effectively retained by the IS, although only 2,4,6-TCA and 2,4,6-TBA are detected by the ELISA used. The immunopurification procedure developed could also be useful as a selective cleanup method prior to chromatographic analysis.

Anisoles↗

Fast and sensitive method to determine chloroanisoles in cork using an internally cooled solid-phase microextraction fiber.

A new generation of solid-phase microextraction (SPME) fiber, an internally cooled fiber (cold fiber with polydimethylsiloxane loading) that allows heating the sample matrix and simultaneously cooling the fiber coating, was used to determine 2,4-dichloroanisole, 2,6-dichloroanisole, 2,4,6-trichloroanisole and pentachloroanisole in cork. A comparison between the cold fiber and regular SPME fiber was performed. An automated headspace solid-phase microextraction (HS-SPME) using commercial fibers and an internally cooled SPME fiber (CF-HS-SPME) coupled to gas chromatography-time-of-flight mass spectrometry (GC-TOF-MS) was used. The extraction conditions for both CF-HS-SPME and HS-SPME were optimized using full factorial design and Doehlert matrix. The best extraction conditions for CF-HS-SPME were obtained using 10 min of incubation time, 10 min of extraction time, and sample and fiber temperature of 130 and 10 degrees C, respectively. For HS-SPME, polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used with 10 min of incubation time, 75 min of extraction time, 85 degrees C of sample temperature, 8 ml of water was added and agitated at 500 rpm. The quantification limits for the target compounds using CF-HS-SPME procedure were between 0.8 and 1.6 ng g(-1) of cork, while for HS-SPME were between 4 and 6 ng g(-1) of cork. Furthermore, the CF-HS-SPME procedure could be used as a non-destructive method after minor modification of the agitator for the autosampler.

Anisoles↗

Comparative study of two chromatographic methods for quantifying 2,4,6-trichloranisole in wines.

Here we present the validation and the comparative study of two chromatographic methods for quantifying 2,4,6-trichloroanisole (TCA) in wines (red, rosé and white wines). The first method involves headspace solid-phase microextraction and gas chromatography with electron-capture detection (ECD). The evaluation of the performance parameters shows limit of detection of 0.3 ng l(-1), limit of quantification of 1.0 ng l(-1), recoveries around 100% and repeatability of 10%. The second one implies a headspace solid-phase microextraction and gas chromatography with mass spectrometric detection. The performance parameters of this second method are limit of detection of 0.2 ng l(-1), limit of quantification of 0.8 ng l(-1) and repeatability of 10.1%. From the comparative study we can state that both methods provide similar results and the differences between them are the better sensitivity of the GC-ECD method and the very shorter chromatogram running time of the GC-MS method. The two methods are able to quantify TCA below the sensorial threshold in red, rosé and white wines using just a calibration graph, thus they could be a very good tool for quality control in wineries.

Anisoles↗