PubMed Health⌕ Search

PubMed · 13669918

Constrictive pericarditis.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K LIAVAAG, A SANDERUD. 1959-05-31. Constrictive pericarditis.. https://pubmed.ncbi.nlm.nih.gov/13669918/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of adhesive systems and flowable composite lining on bond strength of class II restorations submitted to thermal and mechanical stresses.

The purpose of this study was to evaluate the effect of adhesive systems and flowable composite lining on bond strength to gingival margins of Class II restorations after thermal/mechanical stresses. Proximal cavities were prepared in 90 bovine incisors. Teeth were assigned into nine groups (n = 10), according to the combination of bonding agent [Single Bond (SB), Optibond Solo Plus (OP), Prime & Bond NT (NT)] and layer (1 mm) of flowable composite Filtek Flow (FF) [absent, one layer, two layers]. Materials were applied according to manufacturers' instructions, and FF layers were photoactivated separately. Restorations were concluded with composite resin and were submitted to thermal (1000x, 5-55 degrees C) and mechanical stresses (100,000x, 80 N). For microtensile evaluation, slabs from the gingival bonded interface were obtained, tested under tension, and their failure mode was observed by scanning electron microscopy. Bond strength data were analyzed using two-way ANOVA/Tukey's test. No interaction was observed between adhesive systems and FF lining (p = 0.89). Also, no significant difference was found between bond strength values, whether or not FF layers were used (p = 0.33). However, bonding systems demonstrated significant differences (p = 0.01). SB and NT presented means higher than those observed with OP. Fracture modes varied considerably between experimental groups, and a greater frequency of cohesive failures was noted when FF layers were used.

Adhesives↗

Infiltration/evaporation-induced shrinkage of demineralized dentin by solvated model adhesives.

During dentin bonding, solvated adhesive comonomers are applied to water-saturated decalcified dentin matrices. When alcohol-solvated hydrophilic or hydrophobic methacrylate monomers are applied, they chemically remove water and cause matrix shrinkage during comonomer infiltration. Evaporation of solvent induces further shrinkage. The purpose of this work was to compare the shrinkage of water-saturated dentin matrices infiltrated with ethanol- or methanol-solvated 2-hydroxyethyl methacrylate (HEMA), 2,2-bis[4(2-hydroxy-3-methacryloyloxy-propyloxy)-phenyl] propane (BisGMA), or triethyleneglycol dimethacrylate (TEGDMA) at 90/10, 70/30, 50/50, and 30/70 mass fraction % alcohol/monomer before and after evaporation of alcohol. Thin (ca 0.2 mm) disks of human mid-coronal dentin were demineralized and placed in a well beneath the contact probe of a linear variable differential transformer (LVDT). The height of the matrix was measured before and after random application of one of the twelve alcohol/monomer mixtures. Matrix height was measured during infiltration and during solvent evaporation. Between trials, residual monomer was extracted using ethanol. These studies were repeated on specimens in which 100% alcohol was used to substitute for water in the matrix. Both studies revealed that matrices shrink 30-50% but that pretreatment of matrices with alcohol prevents BisGMA phase separations from occurring. Wet bonding with ethanol instead of water permits infiltration of relatively hydrophobic alcohol/monomers.

Adhesives↗