PubMed Health⌕ Search

PubMed · 13670977

[Ultraviolet densitometer].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M S SHIPALOV. [Ultraviolet densitometer].. https://pubmed.ncbi.nlm.nih.gov/13670977/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Measurement of ultrasonic attenuation coefficient in polymer gel dosimeters.

A technique is described for investigation of the ultrasonic attenuation coefficient for evaluation of absorbed dose in polymer gel dosimeters. Using this technique the attenuation coefficient as a function of absorbed dose in PAG and MAGIC polymer gel dosimeters was measured. The ultrasonic attenuation coefficient dose sensitivity for PAG was found to be 2.9 +/- 0.3 dB m(-1) Gy(-1) and for MAGIC gel 4.2 +/- 0.3 dB m(-1) Gy(-1). Unlike previous studies of ultrasonic attenuation in polymer gel dosimeters this technique enables a direct measure of the attenuation coefficient.

Densitometry↗

In situ two-dimensional high-resolution profiling of sulfide in sediment interstitial waters.

A recently developed technique of diffusive gradients in thin films (D6T)-computer-imaging densitometry (CID) was improved to study in situ two-dimensional distributions of sulfide in sediment interstitial waters adjacent to the DGT device. The in situ profiler accumulates sulfide from the sediment interstitial water through a diffusive gel onto a AgI binding gel to form black Ag2S. The amount of sulfide bound in the binding gel is then determined from the gray scale density of the dried binding gel. New gel-making procedures were employed to produce stable, evenly dispersed AgI binding gels and to minimize the darkening of the AgI gel upon exposure to light The improved DGT-CID technique was used to profile the distribution of sulfide in sediment interstitial waters at Delta Marsh, a highly productive Prairie wetland on the south shore of Lake Manitoba, at a vertical and lateral resolution of < or = 0.4 mm. The in situ high-resolution microprofiles revealed unprecedented two-dimensional heterogeneity in sulfide concentrations in the sediment interstitial waters adjacent to the DGT device. The mosaic distribution of oxic and sulfidic microenvironments suggested not only the complexity and heterogeneity of the biogeochemistry of sulfur species and sulfide-binding metals (e.g., Cd, Cu, Pb, Hg, Zn) in sediments but also the capability of aquatic organisms for coping with the sulfidic environment

Densitometry↗

Comparative study of the thermal properties of mud and peat solutions applied in clinical practice.

Different peloids as e.g. mud and peat have been traditionally used for therapeutic purposes successfully, especially of there thermal actions. It was the aim of the experimental study to compare the thermal properties of two peloids, mud and peat, with a view to assessing their thermal effects when they are applied in clinical practice. The studies were carried out using peat of the marsh type of peats (Hochmoor), and curative Pomorie (Bulgaria) mud. As important parameters were determined the specific thermal capacity at constant pressure (Cp), the density of solutions (rho), the cooling rate (m), the coefficient of temperature transfer (a) of solutions and the coefficient of thermal conductivity (lambda) of solutions of peat and curative mud, compared to water bath. The comparative studies of the thermal properties of water and water solutions of peat and curative mud show that the thermal effect of the water bath is substantially smaller than that of the peat and mud applications. This difference is due to a greater extent to the high values of the dynamic viscosity, not allowing cooling by convection and protecting the surface of the skin upon applications of peloid solutions with a higher temperature.

Densitometry↗