PubMed Health⌕ Search

PubMed · 13727955

Precisely constructed polymers.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G NATTA. 1961. Precisely constructed polymers.. https://doi.org/10.1038/scientificamerican0861-33

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

New hydrophilic polymeric resin based on 4-vinylpyridine-divinylbenzene for solid-phase extraction of polar compounds from water.

A 4-vinylpyridine-divinylbenzene (VP-DVB) resin was synthesized to be used for on-line solid-phase extraction process and it was tested for a group of polar compounds. The high specific surface area and the nitrogen content of the VP-DVB sorbent increased the interactions with the polar analytes in the preconcentration process. The sorbent enabled 100 ml of water to be concentrated with recoveries higher than 70% for several polar compounds (including phenol) except for oxamyl (55%) and methomyl (43%). The method was used to analyse water samples by liquid chromatography and UV detection. Linearity was good and detection limits were 0.1-0.2 microg l(-1) for all compounds. Several tap and river water and waste water treatment plant samples were analyzed; phenol and (4-chloro-2-methyl-phenoxy)acetic acid (MCPA) were tentatively determined in some samples.

Polymers↗

Molecularly imprinted polymer sensor arrays.

An eight channel molecularly imprinted polymer sensor array was prepared that was able to differentiate six different aryl amine analytes, including diastereomers with 94% accuracy.

Polymers↗

Performance and application of a new planar array infrared spectrograph operating in the mid-infrared (2000-975 cm(-1)) fingerprint region.

A no-moving-part planar array infrared spectrograph (PA-IR) equipped with a 256 x 256 mercury cadmium telluride (MCT) focal plane array has been designed and constructed. The performance of the instrument, whose frequency range extends from 2000-975 cm(-1), has been assessed in terms of resolution, bandwidth, and signal-to-noise ratio. The PA-IR spectrograph is able to record spectra with an 8.7 ms time resolution and has peak-to-peak noise levels as low as 2.4 x 10(-4) A.U. As a demonstration of the potential of PA-IR, the dynamics of reorientation of a liquid crystalline sample exposed to a single electric field pulse has been studied. It was shown that PA-IR can be used for the simultaneous acquisition of two orthogonally polarized spectra. The advantages and limitations of PA-IR, step-scan Fourier transform infrared (FT-IR), and ultrarapid-scanning FT-IR for real-time studies of reversible and irreversible phenomena are thoroughly discussed.

Polymers↗