Programmed electrical stimulation of the ventricle: an efficient, sensitive, and specific protocol.

Abstract

A relatively simple and efficient ventricular programmed electrical stimulation (PES) protocol was developed, capable of achieving high degrees of sensitivity and specificity. In a series of 481 subjects, 1, 2, and 3 extrastimuli (ES) were used successively during sinus rhythm and ventricular pacing at two drive cycle lengths, at one or more ventricular sites, together with rapid ventricular pacing, and other maneuvers such as isoproterenol infusion. Three ES were used immediately after two ES at each drive rate, rather than returning after completion of the protocol with two ES. Using the protocol, appropriate arrhythmias could be induced in 88% of all patients with ventricular fibrillation, 84% of all patients with sustained ventricular tachycardia (91% with underlying coronary disease), and 58% of patients with severe nonsustained ventricular tachycardia. There were significant differences in inducibility between patients whose ventricular arrhythmias were due to coronary artery disease and other causes. In contrast, sustained ventricular arrhythmias (all ventricular fibrillation) could be induced in only 5% of a control group of control patients, for a specificity of 95%. The protocol described is simpler and more efficient than those that use exhaustive testing of two ES before going to three ES. Three ES during sinus rhythm proved to be the most productive step, with a higher yield ratio (true: false-positives) than two ES or three ES during pacing, especially at faster rates. Greater efficiency is also achieved by leaving the timing of an extrastimulus just beyond its effective refractory period when an additional extrastimulus is to be added, compared to protocols in which the extrastimulus is moved later in the cycle and then decremented in tandem with the additional extrastimulus. Coupling intervals less than 200 msec produced some false-positives, but fewer overall than intervals greater than or equal to 200 msec, and with yield ratios comparable to other protocol steps. The protocol described meets NASPE standards for ventricular programmed stimulation protocols, and with its demonstrated specificity and relative simplicity and efficiency may be useful as a model for groups not yet committed to an alternative protocol.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J D Fisher, S G Kim, K J Ferrick, S G Artoul, D Fink, J A Roth, D R Johnston, H R Williams. 1992. Programmed electrical stimulation of the ventricle: an efficient, sensitive, and specific protocol.. https://doi.org/10.1111/j.1540-8159.1992.tb05139.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Medium-term follow-up and modes of failure following epicardial pacemaker implantation in young children.

AIMS: Young children suffering from congenital or post-operative AV-block require life-long pacemaker stimulation. Due to the anatomical prerequisites initially epicardial electrodes are implanted and the generator is placed in the upper abdominal wall. The following study investigated modes of failure leading to reoperation in this group of technically challenging patients. METHODS AND RESULTS: Between October 2000 and May 2005, a total of 21 infants (age 3 days to 5 years) underwent pacemaker implantation using a subxyphoidal incision for newborns (and a partial lower or complete median sternotomy for older children). Nine patients had previous cardiac surgery for complex congenital defects. The remaining 12 young children suffered from congenital AV-Block (CAVB). Twenty-one bipolar epicardial electrodes (Medtronic Capsure epi) were fixed to the right ventricle, 15 had additional implantation of a bipolar atrial lead. The pacemaker generator (Medtronic Kappa 701) was implanted into the right upper abdominal wall. Indications for revision were recorded. No mortality was observed; pacing and sensing parameters remained stable up to a 5-year follow-up. A total of four reoperations occurred. Three of the four revisions were caused by ventricular electrode fracture. At revision, two electrodes were broken at the crossing between the pericardial cavity and the abdominal wall, one bipolar lead at the Y-division into the two tip electrodes. One reoperation was due to a pacemaker recall. All revisions were performed without complications. CONCLUSION: In our institute epicardial pacing in young children was associated with a satisfactory clinical outcome, but also a significant number of failures leading to reoperation, mainly due to electrode fracture caused by the muscular activity of this patient group. Reoperations were performed at a low risk.

Cardiac Pacing, Artificial↗

Spectral pulsed-wave tissue Doppler imaging lateral-to-septal delay fails to predict clinical or echocardiographic outcome after cardiac resynchronization therapy.

AIMS: The current study sought to assess if pre-implantation lateral-to-septal delay (LSD) > or =60 ms assessed by spectral pulsed-wave myocardial tissue Doppler imaging (PW-TDI) could predict successful long-term outcome after cardiac resynchronization therapy (CRT). METHODS AND RESULTS: Sixty patients (72% males, mean age 59 +/- 10 years) who were referred for CRT according to the ACC/ESC guidelines were enrolled in the study. All patients underwent spectral PW-TDI before and 1 year after CRT. Two left ventricular (LV) dyssynchrony time intervals, T(O) and T(P) (time to onset and peak of LV myocardial velocity, respectively), LSD were recorded. Left ventricular dyssynchrony was defined as LSD > or =60 ms. Clinical response was defined as an improvement in >1 NYHA class plus improvement in 6-min walk distance (6MWD) > or =25%, echocardiographic response was defined as a > or =15% reduction in LV end-systolic volume (LV-ESV). One year after CRT, 50 patients (83%) were clinical responders and 47 patients (78%) were echocardiographic responders. Both T(O) and T(P) LV dyssynchrony indices failed to predict echocardiographic CRT outcome. In addition, there were no significant differences between 'synchronous' and 'dyssynchronous' patient populations at baseline or follow-up in either clinical (NYHA class and 6MWD) or echocardiographic (LV ejection fraction, LV end-diastolic, and end-systolic) variables. CONCLUSION: The great majority of patients referred for CRT benefit clinically from it. However, spectral PW-TDI failed to predict CRT outcome. When PW-TDI dyssynchrony was applied for selection of proper CRT patients, up to 80-86% of the patients with synchronous LSD that had proven clinical and echocardiographic benefit from CRT would have been denied CRT.

Cardiac Pacing, Artificial↗