PubMed Health⌕ Search

PubMed · 13782351

An automatic changer for liquid samples.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

de WAARD. 1960. An automatic changer for liquid samples.. https://doi.org/10.1016/0020-708x(60)90110-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Headspace water-based liquid-phase microextraction.

A new organic-free mode of headspace liquid-phase microextraction termed headspace water-based liquid-phase microextraction has been developed. Five phenols were used as model compounds in the development and evaluation of the procedure. Parameters affecting the extraction efficiency were investigated. Under optimal extraction conditions, very high enrichment factors were achieved. Since only water (with sodium hydroxide to adjust the pH) and a conventional microsyringe were used, this new technique is affordable, efficient, and convenient for extraction of volatile and semivolatile ionizable compounds. In addition, in combination with capillary electrophoresis, the entire analytical process is totally organic solvent-free and is thus environmentally friendly.

Chemistry Techniques, Analytical↗

High-performance genetic analysis on microfabricated capillary array electrophoresis plastic chips fabricated by injection molding.

We have developed a novel technique for mass production of microfabricated capillary array electrophoresis (mu-CAE) plastic chips for high-speed, high-throughput genetic analysis. The mu-CAE chips, containing 10 individual separation channels of 50-microm width, 50-microm depth, and a 100-microm lane-to-lane spacing at the detection region and a sacrificial channel network, were fabricated on a poly(methyl methacrylate) substrate by injection molding and then bonded manually using a pressure-sensitive sealing tape within several seconds at room temperature. The conditions for injection molding and bonding were carefully characterized to yield mu-CAE chips with well-defined channel and injection structures. A CCD camera equipped with an image intensifier was used to monitor simultaneously the separation in a 10-channel array with laser-induced fluorescence detection. High-performance electrophoretic separations of phiX174 HaeIII DNA restriction fragments and PCR products related to the human beta-globin gene and SP-B gene (the surfactant protein B) have been demonstrated on mu-CAE plastic chips using a methylcellulose sieving matrix in individual channels. The current work demonstrated greatly simplified the fabrication process as well as a detection scheme for mu-CAE chips and will bring the low-cost mass production and application of mu-CAE plastic chips for genetic analysis.

Chemistry Techniques, Analytical↗

Polymer nanochannels fabricated by thermomechanical deformation for single-molecule analysis.

A simple method for fabricating nanoscale channels based on thermomechanical deformation of rigid polymer substrates is demonstrated. Polycarbonate preforms containing microchannels with cross-sectional dimensions on the order of tens of micrometers are controllably deformed to produce submicrometer dimensions. The reduced channel dimensions are achieved by heating the preform while applying a uniaxial tensile force to reduce channel cross sections through the Poisson effect. Nanochannels with circular or elliptical cross sections are defined by varying the channel position and preform geometry prior to deformation. Arrays of parallel nanochannels with critical dimensions down to 400 nm are described. Using the fabrication method, a nanochannel network is fabricated for the detection of single protein molecules via confocal fluorescence microscopy. The chip includes a detection channel with cross-sectional dimensions approaching the confocal volume dimensions of the detection optics and a larger adjacent reference channel used to optimize focusing. Detection of fluorescently labeled bovine serum albumin at 15 and 150 nM concentrations is presented, demonstrating the ability to perform single-molecule fluorescence measurements in polycarbonate chips using visible wavelengths for excitation and detection.

Chemistry Techniques, Analytical↗