PubMed Health⌕ Search

PubMed · 13811808

A simple electrode selector system.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R COOPER, W J WARREN. 1959. A simple electrode selector system.. https://doi.org/10.1016/0013-4694(59)90126-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Total protein determinations by particle beam/hollow cathode optical emission spectroscopy.

A novel method for quantitative total protein determinations is presented. Total protein content is determined by particle beam/hollow cathode optical emission spectroscopy (PB/HC-OES) through monitoring of carbon atomic emission. The PB/HC-OES offers such advantages as ease of operation, exclusion of labor-intensive sample pretreatment processes, rapid analysis, high sensitivity, and low detection limit. The method could also be adapted to be integrated to current microfluidics devices. Parametric optimization for sample introduction, nebulization, desolvation, and hollow cathode source conditions is performed for the analysis of aqueous bovine serum albumin solutions. Response curves of C (I) 193.0-nm emission were obtained under the optimized conditions with both 10% HCl and 100 micromL KCl added to the sample matrix as potential carriers. The detection limit for triplicate injections of bovine serum albumin standards was found to be on the single-nanogram level with 200-microL injections. The addition of KCl significantly improved the sensitivity, supporting the proposed "carrier effect" of chloride salts in the particle transport process. Results obtained here suggest a range of applications for the use of the PB/HC-OES source for total protein determinations; emphasis here is future use in assessing protein quantification in microfluidic systems.

Electrodes↗

A thin, flexible multielectrode grid for high-density surface EMG.

Although the value of high-density surface electromyography (sEMG) has already been proven in fundamental research and for specific diagnostic questions, there is as yet no broad clinical application. This is partly due to limitations of construction principles and application techniques of conventional electrode array systems. We developed a thin, highly flexible, two-dimensional multielectrode sEMG grid, which is manufactured by using flexprint techniques. The material used as electrode carrier (Polyimid, 50 microm thick) allows grids to be cut out in any required shape or size. One universal grid version can therefore be used for many applications, thereby reducing costs. The reusable electrode grid is attached to the skin by using specially prepared double-sided adhesive tape, which allows the selective application of conductive cream only directly below the detection surfaces. To explore the practical possibilities, this technique was applied in single motor unit analysis of the facial musculature. The high mechanical flexibility allowed the electrode grid to follow the skin surface even in areas with very uneven contours, resulting in good electrical connections in the whole recording area. The silverchloride surfaces of the electrodes and their low electrode-to-skin impedances guaranteed high baseline stability and a low signal noise level. The electrode-to-skin attachment proved to withstand saliva and great tensile forces due to mimic contractions. The inexpensive, universally adaptable and minimally obstructive sensor allows the principal advantages of high-density sEMG to be extended to all skeletal muscles accessible from the skin surface and may lay the foundation for more broad clinical application of this noninvasive, two-dimensional sEMG technique.

Electrodes↗