PubMed Health⌕ Search

PubMed · 13847982

[Postoperative serum copper level changes].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M ZWICKER. 1959-09-01. [Postoperative serum copper level changes].. https://doi.org/10.1007/bf01478513

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper↗

Distribution and remobilization of iron and copper in wheat.

BACKGROUND AND AIMS: The amount of iron (Fe) and copper (Cu) that is loaded into grains of wheat (Triticum aestivum) depends on both the amount of nutrient taken up by the plant post-anthesis and the amount that is remobilized from vegetative organs as they senesce. Previous reports have shown that these two micronutrients behave quite differently in wheat in that Cu is readily remobilized to the grain whilst Fe shows poor remobilization. The object was to quantify the distribution of Fe and Cu in wheat and to show how this distribution changes from anthesis to grain maturity. METHODS: The uptake and distribution of both Fe and Cu were investigated in wheat grown at two levels, adequate and low, of both micronutrients. Plants were grown in sand culture and the main culms were harvested at anthesis, 18 days post-anthesis and at maturity. Plants were separated into various organs and analysed for Fe and Cu using ICP-OES. KEY RESULTS: There was good remobilization of Fe from the rest of the shoot to the grain with 77 % of the total shoot Fe in the grain at maturity. In the adequate-Cu treatment there was 62 % of the total plant Cu in the grain at maturity, whereas in the low-Cu treatment this was only 40 %. There was no net Fe taken up into the above-ground plant parts post-anthesis whilst for Cu there was. The remobilization evident for Fe and Cu was greater than that found for zinc and much greater than evident for manganese in the same material. CONCLUSIONS: The results reported here represent good evidence for the high reproductive mobility of both Fe and Cu in wheat.

Copper↗

Electrodialytic remediation of copper mine tailings.

Mining activities in Chile have generated large amounts of solid waste, which have been deposited in mine tailing impoundments. These impoundments cause concern to the communities due to dam failures or natural leaching to groundwater and rivers. This work shows the laboratory results of nine electrodialytic remediation experiments on copper mine tailings. The results show that electric current could remove copper from watery tailing if the potential gradient was higher than 2 V/cm during 21 days. With addition of sulphuric acid, the process was enhanced because the pH decreased to around 4, and the copper by this reason was released in the solution. Furthermore, with acidic tailing the potential gradient was less than 2 V/cm. The maximum copper removal reached in the anode side was 53% with addition of sulphuric acid in 21 days experiment at 20 V using approximately 1.8 kg mine tailing on dry basis. In addition, experiments with acidic tailing show that the copper removal is proportional with time.

Copper↗