Certainty factor theory and its implementation in a medical expert system shell.

Abstract

In this article some topics related to the MYCIN-model for uncertainty handling are discussed. First, it is pointed out that one of the problems identified by Adams should be considered as evidence supporting the point of view that the probabilistic interpretations of measures of belief and measures of disbelief given by Shortliffe are inappropriate. In this context some results achieved by Heckerman are reviewed, and it is shown that similar problems can be identified in the interpretation given by him. It is also pointed out that Heckerman's argument that the original probabilistic interpretation of certainty factors implies non-commutative evidence-updating is not correct. Then, in the context of the result achieved by Horvitz and Heckerman, in which it was proven that there is an isomorphic mapping from the evidence combination scheme for the likelihood ratio to the evidence combination function in EMYCIN and its successors, it is pointed out that the evidence combination scheme for the likelihood ratio suffers from a great restriction on its applicability in expert systems. Subsequently, some short remarks are made with respect to the complaint that sometimes the MYCIN model cannot work as well as expected. Lastly implementation of the certainty factor mechanism in a HIS-oriented expert system shell with some substantial changes is described.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Q Dan, J Dudeck. Certainty factor theory and its implementation in a medical expert system shell.. https://doi.org/10.3109/14639239209085013

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Performance of the FearID earprint identification system.

The Forensic Ear Identification (FearID) research project was started in order to study the strength of evidence of earprints found on crime scenes. For this purpose, a sample of earprints from 1229 donors over three countries was collected. From each donor three left and three right earprints were gathered. On the one hand, operators denoted contours of the earprints to facilitate segmentation of the images, on the other anthropological specialists denoted anatomically specific locations. On the basis of this, methods for automated classification were developed and used for training of a system that classifies pairs of prints as 'matching' or 'non-matching'. Comparing lab quality prints, the system has an equal error rate of 4%. Starting from a reference database containing two prints per ear, hitlist behaviour is such that in 90% of all query searches the best hit is in the top 0.1% of the list. The results become less favourable (equal error rate of 9%) for print/mark comparisons.

Databases, Factual↗

Normal limits of ejection fraction and volumes determined by gated SPECT in clinically normal patients without cardiac events: a study based on the J-ACCESS database.

PURPOSE: Quantitative gated single-photon emission computed tomography (SPECT) is known to have high accuracy and precision for measurement of the principal cardiac functional parameters. We hypothesised that normal values for EF and LV volumes may differ among nationalities, and that optimal threshold values specific to the study population are required. METHODS: Among 4,670 consecutively registered patients for a J-ACCESS (Japanese investigation regarding prognosis based on gated SPECT) study from 117 hospitals, a total of 268 (149 women, 119 men) were selected who had no baseline cardiac diseases and had experienced no cardiac events during the preceding 3-year period. A gated SPECT study was performed with 99mTc-tetrofosmin and analysed with Cedars Sinai Medical Center's quantitative gated SPECT (QGS) software. The results in respect of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) and stroke volume (SV), and EDV, ESV and SV normalised by body surface area (EDVI, ESVI and SVI), were calculated and summarised to obtain normal limits. RESULTS: EF for women and men was 74 +/- 9% and 63 +/- 7%, respectively (p < 0.0001). EDV, ESV and SV were significantly smaller in women than in men. Based on multiple regressions for linear models, the primary and secondary predictors of EF, EDVI, ESVI were gender and age. By stepwise multiple regression analysis, a statistically significant third predictor for EDV, ESV, SV and SVI was body weight. No colinearity was found between age and body weight. Important factors for the studied Japanese population included a high incidence of small hearts in women and the relatively advanced age of the population (the mean age +/-SD was 64.1 +/- 10.0 years for women and 60.9 +/- 11.7 years for men). CONCLUSION: EF and volumes determined by gated SPECT with QGS were significantly affected by gender and age, with body weight as a third predictor for volumes. Moreover, the normal limits were so specific for the population studied that standards appropriate for the study in question should be utilised.

Databases, Factual↗