PubMed Health⌕ Search

PubMed · 14151341

[VARIOUS PROBLEMS IN PREDIABETES].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A HORIUCHI. 1964. [VARIOUS PROBLEMS IN PREDIABETES].. https://pubmed.ncbi.nlm.nih.gov/14151341/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evaluation of the Glucometer Elite XL device for screening for neonatal hypoglycaemia.

UNLABELLED: To prevent persistent neurodevelopment and physical growth deficits in neonatal care, it is mandatory to determine blood glucose levels as quickly and precisely as possible, preferably using micro-methods. However, most commercially available instruments have not been validated and approved for this purpose. The aim of this study was to validate the Glucometer Elite XL, a newly developed device for point-of-care testing (POCT). In samples from 869 newborn infants, glucose levels were simultaneously measured by the Glucometer Elite XL in whole blood and by an accepted clinical laboratory method in haemolysed blood using the ECA 2000 device. An acceptable method agreement was found between the POCT and the ECA 2000 method (mean difference 0.013 mmol/l, SD 0.69). As determined by regression analysis (Passing-Bablok), the slope was 1.086 with a y-intercept of -0.4 mmol/l ( r =0.959, P <0.05). The differences between measurement pairs of both assays versus the haematocrit were negligible. With a cut-off for hypoglycaemia at 2.6 mmol/l glucose in haemolysed blood, the sensitivity of the POCT device was 0.63 and specificity was 0.98. Raising the cut-off of the Glucometer Elite XL to 3.2 mmol/l, the sensitivity and specificity incremented to 1.0 and 0.89, respectively. CONCLUSION: The Glucometer Elite XL instrument can be recommended for point-of-care blood glucose measurement in newborn infants if its character as a screening method is taken into account. To compensate deviating results, we advise to shift its cut-off for hypoglycaemia recognition to a safe threshold of 3.2 mmol/l. However, hypoglycaemia has to be confirmed by a valid glucose measurement in the clinical laboratory.

Blood Chemical Analysis↗

The Prometheus device for extracorporeal support of combined liver and renal failure.

BACKGROUND/AIMS: Prometheus is a newly developed extracorporeal liver support system that combines removal of albumin-bound substances (adsorption on resin adsorbers) and water-soluble substances (diffusion during high-flux hemodialysis). Therefore, it is a promising treatment option for patients with hepatorenal syndrome (HRS). METHODS: We studied 10 patients with HRS in a prospective clinical study. All patients underwent 2 consecutive Prometheus treatments. A variety of clinical and biochemical parameters were assessed. RESULTS: Prometheus treatment was uncomplicated and safe. A statistically significant improvement of serum creatinine and urea concentrations as well as blood pH was observed after Prometheus treatment. Furthermore, liver detoxification was supported by a significant decrease of serum levels of conjugated bilirubin, bile acids and ammonia. CONCLUSIONS: Prometheus is a safe treatment for patients with HRS. Both, albumin-bound and water-soluble substances were effectively removed. Controlled studies will evaluate the effect of this new treatment option on survival in patients with HRS.

Blood Chemical Analysis↗

Interventions to regulate ordering of serum magnesium levels: report of an unintended consequence of decision support.

BACKGROUND: Unintended consequences of computerized patient care system interventions may increase resource use, foster clinical errors, and reduce users' confidence. OBJECTIVE: To evaluate three successive interventions designed to reduce serum magnesium test ordering through a care provider order entry system (CPOE). The second, modeled after a previously successful intervention, caused paradoxical increases in magnesium test ordering rates. DESIGN: A time-series analysis modeled weekly rates of magnesium test ordering, underlying trends, the impact of the three successive interventions, and the impact of potential covariates. The first intervention exhorted users to discontinue unnecessary tests recurring more than 72 hours into the future. The second displayed recent magnesium, calcium, and phosphorus test results, limited testing to one test instance per order, and provided education regarding appropriate indications for testing. The third targeted only magnesium ordering, displayed recent results, limited testing to one instance per order, summarized indications for testing, and required users to select an indication. PARTICIPANTS: Clinicians at Vanderbilt University Hospital, a 609-bed academic inpatient tertiary care facility, from 1998 through 2003. MEASUREMENTS: Weekly rates of new serum magnesium test orders, instances, and results. RESULTS: At baseline, there were 539 magnesium tests ordered per week. This decreased to 380 (p = 0.001) per week after the first intervention, increased to 491 per week (p < 0.001) after the second, and decreased to 276 per week (p < 0.001) after the third. CONCLUSION: A clinical decision support intervention intended to regulate testing increased test order rates as an unintended result of decision support. CPOE implementers must carefully design resource-related interventions and monitor their impact over time.

Blood Chemical Analysis↗