PubMed Health⌕ Search

PubMed · 14240809

COMPLETE DENTURE CONSTRUCTION FOR DENTURE-WEARERS.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R MESSINGER. 1965. COMPLETE DENTURE CONSTRUCTION FOR DENTURE-WEARERS.. https://pubmed.ncbi.nlm.nih.gov/14240809/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Wear and superficial roughness of glass ionomer cements used as sealants, after simulated toothbrushing.

The purpose of this study was to evaluate, in vitro, the properties (wear and roughness) of glass ionomer cements that could influence their indication as pit and fissure sealants. The utilized materials were Fuji Plus, Ketac-Molar and Vitremer (in two different proportions: 1:1 and :1). The resin-based sealant Delton was used as control. By means of an electronic balance (precision of 10-4 g), wear was measured in function of weight loss after simulated toothbrushing. Superficial roughness was determined by means of a surface roughness-measuring apparatus. The results revealed that diluted Vitremer and Fuji Plus were less resistant to toothbrushing abrasion and had the greatest increase in superficial roughness. Although in clinical situations luting or diluted ionomer cements are often utilized as alternatives to resin-based sealants, the resultsof this study revealed that the properties of those cements are worse than those of restorative ionomers, whichpresented results similar to those of the evaluated resin sealant.

Dental Restoration Wear↗

Physico-mechanical properties of a fast-set highly viscous GIC restorative.

UNLABELLED: The fast-setting reaction of 'fast-set' highly viscous glass-ionomer cements (GIC) may result in superior mechanical properties and good wear resistance as the material can theoretically achieve sufficient strength to resist masticatory loads within a shorter time. The aim of this study was to determine the hardness, strength (compressive and diametral tensile) and wear resistance of a 'fast-set' highly viscous GIC (Fuji IX GP Fast). Its regular set counterpart (Fuji IX GP) was used for comparison. The glass powders of the two cements were also characterized. Hardness testing [Vickers' hardness number (VHN)] was performed with a digital hardness tester (load=50 g; dwell time=30 s) and compressive/diametral tensile strength testing (MPa) was conducted based upon British Standards specification for GICs (BS6039, 1981). Wear testing was conducted using a reciprocal compression-sliding wear instrumentation at 20 MPa contact stress against SS304 counter-bodies with distilled water as lubricant. All specimens were immersed in distilled water at 37 degrees C and tested 24 h after start of mixing. Further mechanical tests (hardness and strength) were conducted with specimens stored for 1 week in distilled water at 37 degrees C. The glass powders were characterized using laser particle sizing, standard electron microscope (SEM) and energy dispressure X-ray (EDX) analysis. Results were analysed using multiple analysis of variance (manova) and independent samples t-test at significance level 0.05. No significant difference in hardness, compressive and diametral tensile strength was observed between Fuji IX GP and Fuji IX GP Fast at 1 day. There was also no significant difference in wear at all cyclic intervals. Although the difference in strength was not significant between the two cements at 1 week, Fuji IX GP Fast was significantly harder than Fuji IX GP. Particle size of both cements ranged from 0.3 to 200 microm. The mean particle sizes were, however, different and were 13.43 and 7.13 microm for Fuji IX GP and Fuji IX GP Fast, respectively. Fuji IX GP Fast offers no other advantage over Fuji IX GP with the exception of improved hardness. CLINICAL RELEVANCE: Besides being harder, the fast-set highly viscous GIC restorative offers no other physico-mechanical advantage over its regular set counterpart.

Dental Restoration Wear↗

Softening patterns of light cured glass ionomer cements.

OBJECTIVE: The aim of this study was to determine the effects of commonly used food simulating solutions and sodium hydroxide on the softening of light cured glass ionomer cements. METHODS: Four types of light cured glass ionomers (classified on the basis of the liquid component) as follows: (1) materials that combine a polymerizable monomer and polyalkenoic acid (PMPA); (2) use of a polymerizable polyalkenoic acid (PPA); (3) acid monomer (AM) in place of the polyalkenoic acid; and (4) replacement of polyalkenoic acid with polymerizable monomer (PMPR). A traditional glass ionomer and a microfil composite were used as controls. Disc-shaped specimens aged for a week at 37 degrees C and 100% relative humidity were stored in water, ethanol, heptane and 0.1 M sodium hydroxide for a period of 28 days. Barcol hardness measurements were made before immersion as well as at intervals of 24 h, 3 days, 7 days and 28 days after immersion. RESULTS: In general the softening effect was lowest on the resin composite control. Hardness could not be measured for the traditional glass ionomer after 24 h due to breakage and dissolution of samples. The different solutions had varying effects on the different classes of light cured glass ionomers. The change in hardness after 28 days ranged from an increase of +6.7% for PMPA material in heptane to a complete disintegration of PPA amd PMPR in NaOH at 60 degrees C. SIGNIFICANCE: The softening effect of food simulating solutions is dependent on the formulation of light cured glass ionomers. In clinical use, the role of softening in wear will consequently vary.

Dental Restoration Wear↗