PubMed Health⌕ Search

PubMed · 1424758

Lumbosacral spine imaging: physioanatomic method.

Abstract

Noninvasive evaluation of low back and leg pain has progressed rapidly over the past decade. The development of computed tomography, single-photon emission-computed tomographic bone scan, and magnetic resonance imaging has markedly increased diagnostic accuracy in detecting pathologic conditions. With this increased accuracy has come recognition of a 50% prevalence of underlying abnormalities in patients between 20 and 60 years old who have no symptoms. When such patients have a back injury, subsequent imaging will show in half of the population studied abnormalities that are not related to an acute injury. Degeneration of the spine progresses in all patients throughout their lifetime, and nearly all of the population will have back discomfort at some time. Political- and judicial-based compensation for back injuries related to accidents and on-the-job injuries provides an incentive for patients not to improve on therapy and to exaggerate symptoms, further complicating the clinical evaluation of their condition. The goal of physioanatomic noninvasive and invasive imaging evaluation presented in the following chapters is to increase specificity by differentiating pain generators from asymptomatic underlying pathologic conditions. When used with intensive conservative management and psychologic testing, this physioanatomic approach has resulted in much better treatment outcomes in our experience. The physioanatomic approach is quite simple, consisting of rigorous correlation of pathologic changes demonstrated by noninvasive imaging modalities (computed tomography, single-photon emission-computed tomographic bone scan, and magnetic resonance), or invasive modalities (diskography-enhanced computed tomography, nerve root block and facet block) with the patient's symptoms to evaluate whether the symptoms and the pathologic lesion are concordant or discordant. Patient symptoms and history are evaluated by use of a pain drawing and information sheet. The patient's pain pattern is categorized into a nonspecific pattern or into one of four recognizable pathway patterns (radicular, dorsal ramus, polyneuropathy, and sympathetic). Because each spinal lesion is typically manifested primarily via one of the four symptom pathways, the distribution of expected symptoms from each pathologic feature can be compared with the patient's pain drawing, and an assessment of the significance of imaged lesions can be made. The patient's presenting symptoms are also used to determine the most cost-effective and efficacious use of initial diagnostic imaging evaluation. In a minority of patients the findings on noninvasive imaging either will not correlate with the patient's symptoms or will demonstrate multiple abnormalities that could account for the patient's symptoms. In these patients, invasive techniques are extremely helpful in defining a pain generator or pain generators.(ABSTRACT TRUNCATED AT 400 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P R Luers. Lumbosacral spine imaging: physioanatomic method.. https://doi.org/10.1016/0363-0188(92)90018-b

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗