PubMed Health⌕ Search

PubMed · 14369872

[A modern electron microscope].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E RUSKA. 1955-03-03. [A modern electron microscope].. https://pubmed.ncbi.nlm.nih.gov/14369872/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Technical note: reconstructing dose distributions from manually planned electron boosts in breast radiotherapy.

PURPOSE: In breast radiotherapy, delivery of manually-calculated electron boosts limits retrospective dose-response analyses as dose distribution is unavailable. This work evaluates the feasibility of reconstructing dose distributions from manually planned electron boosts in breast-conserving radiotherapy. METHODS: Only 72 out of 198 breast cancer patients had complete stored dose distributions from sequential electron boosts in the REQUITE study. Arbitrary data from 70/72 patients were used to develop and validate dose reconstruction method. Twenty patients were used to determine optimal parameters for Monte-Carlo-based (MC) electron dose reconstruction on RayStation (v.11B-R), considering CT-calibration curve, MC-history number, andcalculation grid resolution. Remaining 50 patients were used to quantify dose reconstruction accuracy. The similarity between reconstructed and stored dose was evaluated using 3D-gamma index and dosimetric parameters extracted from breast and tumour bed contours. Dose difference location was evaluated using dose-location histogram. RESULTS: Calculation grid resolution significantly impacted electron dose distribution (p&#xa0;<&#xa0;0.01), where the finest grid (0.15&#xa0;cm) showed highest similarity to stored doses. CT-calibration curve and MC-history number had a negligible influence on dose reconstruction. Dosimetric difference between reconstructed and stored doses was&#xa0;<&#xa0;1&#xa0;Gy for breast and tumour bed. Reconstructed dose was achieved&#xa0;>&#xa0;90% gamma passing rate in the validation set. However, around 2.5&#xa0;Gy dose differences were observed at the skin and tissue interface regions. CONCLUSIONS: Retrospective electron boost dose reconstruction is feasible with acceptable accuracy, and could increase data completeness in large cohort studies. Caution is advised when assessing dose near tissue interface and further validation is needed outside the REQUITE dataset.

Electrons↗

Theoretical study of [ XN5]- (X = O, S, Se, Te) systems.

A series of [XN5]- (X = O, S, Se, Te) compounds has been examined with ab initio and Density Functional Theory (DFT) methods. The five-membered nitrogen ring series of structures are global minima and may exist or be characterized due to their significant dissociation barriers (29.7-32.7 kcal mol(-1)). Nucleus-independent chemical shifts (NICS) criteria and the presence of (4n+2) pi-electrons confirmed that the five-membered nitrogen ring in their structures exhibits characteristics of aromaticity. Thus, the strong stability of the five-membered nitrogen ring structures may be attributed partially to their aromaticity.

Electrons↗

Role of electron density and magnetic couplings on the nucleus-independent chemical shift (NICS) profiles of [2.2]paracyclophane and related species.

The nucleus-independent chemical shifts (NICS) and electron density profiles along the inner and outer regions defined by the two stacked aromatic rings of [2.2]paracyclophane have been analyzed and compared to those of free benzene and p-xylene and benzene dimers taken as reference models. It is found that stacked aromatic rings show a reduction of the NICS indicator of aromaticity as compared to the same free aromatic systems. This decrease of the NICS values upon stacking is not due to an increase of the electron density in the inner region between the rings (as claimed in a previous work) but is related to the magnetic couplings between superimposed rings that affect this measure of local aromaticity. The increase of local aromaticity in superimposed aromatic rings indicated by NICS is not real but the result of the coupling between the magnetic fields generated by the two stacked rings. This result warns about the use of NICS as a descriptor of aromaticity for species having superimposed aromatic rings.

Electrons↗