Porous polyurethane vascular prostheses with variable compliances.

Abstract

A new technique for the preparation of porous vascular prostheses was investigated. Polyurethane solution (5 to 15 wt%) was injected into a mold. After freezing at low temperature (0 degrees C-196 degrees C), solvents were dissolved out with water at 0 degrees C to form porous tubes. The average pore size (several microns to 70 microns), pore occupation (10% to 51%), and compliance (3% to 35%) were easily changed by changing polyurethane concentration, freezing temperature, and freezing methods. Compliances could be decreased gradually by heat treatment. This technique can give a proper pore size (30-60 microns) for tissue ingrowth, and a suitable compliance for matching with arteries and veins. This method might give a desired compliant graft for artificial implantation with the presently valid medical polymers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Q Liu, M Kodama. 1992. Porous polyurethane vascular prostheses with variable compliances.. https://doi.org/10.1002/jbm.820261108

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Leiomyosarcoma of the superior mesenteric vein: a diagnostic and therapeutic challenge.

We report here a case of a very rare entity, a leiomyosarcoma of the mesentericoportal trunk, which was initially misdiagnosed as an unresectable pancreatic cancer invading the mesenteric vein, and which was finally treated by pancreatectomy with mesentericoportal reconstruction. The pitfalls of diagnosis and modalities of resection are discussed.

Blood Vessel Prosthesis↗

The evidence for cerebral protection: an analysis and summary of the literature.

It has been considered likely that the majority of cerebral ischaemic episodes following carotid artery stenting are due to cerebral embolisation. It is intuitive therefore, to attempt to prevent these presumptive emboli, whether they are comprised of air or formed elements, from reaching the brain. Various pharmacological and mechanical solutions are being used. The available literature is hampered by comparisons against historical controls of unprotected CAS with many confounding variables that may influence outcome. There is no clinical Level-I evidence to support the use of protection devices but Level-III and Level-IV evidence suggest benefit.

Blood Vessel Prosthesis↗