A carbon dioxide flowmeter.

Abstract

A simple and inexpensive uroflowmeter has been designed that uses a common carbon dioxide cystometer. The patient voids urine in a specially designed container connected at the bottom of the carbon dioxide source in the cystometer. After proper calibration (500 cc fluid for a 20 mm. deflection in the paper) the patient is asked to void while carbon dioxide flows through the container and the paper recording commences. Any change of volume in the container produces a change in the pressure recorded by the cystometer, which will allow us to know, following calibration, the 2 factors involved in flow: 1) volume voided and 2) time. A table of average flow is available for a quick reading of the findings only by superimposing the table on the uroflow study. The only attachment needed for the cystometer is the special container. Our results support the use of this economical new way to determine urinary flow.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Raz, J Martin, J J Kaufman. 1977. A carbon dioxide flowmeter.. https://doi.org/10.1016/s0022-5347(17)58288-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Characterization of CO2/carbonic acid mediated proton flux through phosphatidylcholine vesicles as model membranes.

The apparent proton permeability coefficient for phospholipid vesicles measured in our laboratory (Norris, F. A. and Powell, G. L. (1990) Biochim. Biophys. Acta 1030, 165-171) for proton flux initiated by rapidly lowering of the external pH (acid jump) was a linear function of the reciprocal internal proton concentration. This behavior was ascribed to the presence of the weak acid carriers, carbonic acid/CO2/bicarbonate. In the present work, a theoretical description, appropriate for proton transport by any weak acid carrier, has been developed which lends itself to novel graphical treatment permitting the separate estimation of the permeability coefficients for protons, hydroxide ions and bicarbonate. The proton permeability coefficient determined by this method was 1.8 x 10(-5) (S.E. 1.3 x 10(-5)) cm/s; that for hydroxide ion was 3.8 x 10(-5) (S.E. 5.6 x 10(-6)) cm/s and a lower limit for the permeability of bicarbonate ion, 4.3 x 10(-6) (S.E. 3.6 x 10(-7) cm/s, can be set. The presence of negative surface charge on the lipid bilayer increased the observed proton permeability coefficient in accordance with Gouy-Chapman theory. The charge was introduced by preparing vesicles containing increasing amounts of negatively charged dioleoylphosphatidylglycerol. The observed proton permeability coefficient increased and the observed permeability coefficients for hydroxide ion and bicarbonate decreased. The addition of the lipophilic cations, valinomycin-K+ and tetrabutylammonium ion increased the slope of P vs. 1/[Hi+]. These changes are analogous to those reported for the permeant weak acid uncouplers FCCP and CCCP. These studies demonstrated that CO2/carbonic acid was an effective carrier of protons across phospholipid model membranes.

Carbon Dioxide