PubMed Health⌕ Search

PubMed · 14503761

Unicondylar arthroplasty: redefining itself.

Abstract

Unicondylar knee arthroplasty is in the process of redefining itself. Increasing numbers of UKAs are being performed throughout the world, with some centers claiming that approximately 30% of their patients are candidates for this procedure. Because recovery from minimally invasive UKA can be rapid with a short or even overnight hospital stay, surgeons are broadening their indications for this procedure. I have concerns toward overuse of UKA. The procedure remains technically demanding and unforgiving. Conservative patient selection is advised and the fine points of the surgical technique should be learned through a moderately invasive patella-subluxing exposure before adapting minimally invasive techniques. The key to a rapid recovery following UKA is subluxing the patella rather than dislocating and everting the quadriceps mechanism. Unicompartmental knee arthroplasty is the right operation for the right patient when performed by the right surgeon using the right surgical technique.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Richard D Scott. 2003. Unicondylar arthroplasty: redefining itself.. https://doi.org/10.3928/0147-7447-20030901-30

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The computer-assisted sequential lateral soft-tissue release in total knee arthroplasty for valgus knees.

Soft-tissue management is a critical factor in total knee arthroplasty, especially in valgus knees. The stepwise release has been based upon surgeon's experience. Computer-assisted surgery has gained increasing scientific interest in recent times and allows the intraoperative measurement of leg axis and gap size in extension and flexion. We therefore aimed to analyse the effect of sequential lateral soft-tissue release and the resulting change in the a.p. limb axis on the one hand and the tibiofemoral gaps on the other hand in extension as well as in flexion in eight cadaveric knees. Measurements were obtained using a CT-free navigation system. In extension the highest increase compared to the previous release step was found for the first (iliotibial band, P = 0.002), second (popliteus muscle, P = 0.0003), third (LCL, 0.007) and the sixth (entire PCL, P = 0.001) release step. In 90 degrees flexion all differences of the lateral release steps were statistically significant (P < 0.004). Massive progression of the lateral gap in flexion was found after the second (popliteus muscle, P = 0.004) and third (LCL, 0.007) release step. Computer-assisted surgery allows measurement of the effect of each release step of the sequential lateral release sequence and helps the surgeon to better assess the result.

Arthroplasty, Replacement, Knee↗

Isolated patellofemoral osteoarthritis.

Isolated patellofemoral osteoarthritis is now recognised to be more common than previously thought. The features and management are reviewed, including the various surgical options in symptomatic patients. The evidence base for managing patellofemoral osteoarthritis is behind that for the tibiofemoral joint. All treatments are based on uncontrolled observational case series, typically retrospectively reviewed. Fortunately the majority of patients with isolated patellofemoral degenerative changes do not need surgical treatment. Those who are symptomatic can usually be successfully treated with weight loss and quadriceps strengthening exercises.

Arthroplasty, Replacement, Knee↗

Stress analysis of the anterior tibial post in posterior stabilized knee prostheses.

Recent retrieval studies have indicated a high incidence of polyethylene wear on the anterior tibial post caused by impingement. This study investigated the influences of post-cam design features and component alignment on the stress distribution in the anterior tibial post when subjected to the impingement loading. Two three-dimensional finite element models of posterior stabilized knee prostheses were constructed, one with flat on flat (FF) and another with curve on curve (CC) contact surfaces between anterior tibial post and femoral cam. The polyethylene insert was modeled with elastoplastic properties. Nine cases, three hyperextension angles (0 degrees , 5 degrees , and 10 degrees ) combined with three axial tibial rotations (0 degrees , 2.5 degrees , and 5 degrees ) simulating different component alignments were analyzed. A vertical compressive load of 2,000 N and an extension moment of 45 Nm were applied simultaneously. The FF model had larger stress increases than the CC model in both hyperextension and tibial rotation compared with the neutral position. The maximum increase for the FF model was 68% in peak contact stress, 125% in von Mises stress, and 58% in tensile stress in the extreme case of 10 degrees of hyperextension combined with 5 degrees of axial rotation. Stress concentration was found at the anterior corner of the post in the FF model; this was not found in the CC model. The curve on curve design can reduce edge loading on the tibial post, especially during axial tibiofemoral rotation.

Arthroplasty, Replacement, Knee↗