Bone marrow cell differential counts obtained by multidimensional flow cytometry.

Abstract

Five-dimensional flow cytometric analysis of normal bone marrow aspirates was utilized to determine the frequency of neutrophils, eosinophils, monocytes, lymphocytes, nucleated erythrocytes, reticulocytes, platelets, and a cell population that included blasts of each of the cell lineages, megakaryocytes, plasma cells, and basophils. Each of these bone marrow cell populations had unique features with respect to forward light scatter, orthogonal light scatter, and staining with Thiazole-Orange, LDS-751, and CD45 labeled with Phycoerythrin (PE). The identity of the cell populations was verified by sorting each of the cell populations and subsequent light microscopic examination of the cells. The frequencies of the nucleated bone marrow cell subpopulations of 50 normal donors were for neutrophils, mean 72.3%; SD +/- 5.1; 95% limits, 70.9-73.8%; eosinophils, mean 1.8%; SD +/- 1.3; 95% limits, 1.4-2.1%; monocytes, mean, 2.8%; SD +/- 1.2; 95% limits, 2.5-3.1%; lymphocytes, mean 12.1%; SD +/- 3.6; 95% limits 11.1-13.2%; nucleated erythrocytes, mean 8.9%; SD +/- 3.9; 95% limits, 7.8-10.1%; and the cell population that included blasts of each of the cell lineages, megakaryocytes, plasma cells, and basophils, mean 1.6%; SD +/- 1.2; 95% limits, 1.3-1.9%. The percentage of reticulocytes in bone marrow aspirates from 50 normal donors correlated with the reticulocyte frequency in the peripheral blood of these donors. However, the mean frequency of reticulocytes was significantly greater (p < 0.0001) in bone marrow (mean 2.19%; SD +/- 0.88) than in peripheral blood (mean 1.71%; SD +/- 0.88). The technique could discriminate between immature and mature reticulocytes based on the brighter staining with both Thiazole-Orange and LDS-751 of the immature reticulocytes. This was confirmed by cell sorting of both reticulocyte populations, which revealed larger clumps of New Methylene Blue staining material in the brighter Thiazole-Orange and LDS-751 stained reticulocytes. The immature reticulocytes were present in normal bone marrow, but not in normal peripheral blood. As expected, a significantly greater frequency of nucleated cells was found in bone marrow aspirates (mean 0.85%; SD +/- 0.59) than in peripheral blood (mean 0.20%; SD +/- 0.11). The frequency of platelets was significantly lower in bone marrow (mean 1.24%; SD +/- 0.69) than in peripheral blood (mean 2.94%, SD +/- 1.14). Flow cytometric bone marrow analysis can provide clinical laboratories with a technique that generates quantitative bone marrow cell differentials and potentially can reduce the need for light microscopic examination of bone marrow smears.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L W Terstappen, J Levin. 1992. Bone marrow cell differential counts obtained by multidimensional flow cytometry.. https://pubmed.ncbi.nlm.nih.gov/1450429/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Design, synthesis and biological evaluation of hydroxybenzothiazole-linked benzothiazole/benzoxazole conjugates as potent dual &#x3b1;-amylase and &#x3b1;-glucosidase inhibitors.

The current study focuses on the synthesis and evaluation of novel Hydroxybenzothiazole-Linked Benzothiazole/Benzoxazole Conjugates to target Diabetes Mellitus (DM) by inhibiting &#x3b1;-amylase and &#x3b1;-glucosidase. Spectroscopic methods, including 1H and 13C NMR spectroscopy, were employed to confirm the structures of newly synthesized conjugates. The findings of in-vitro analysis displayed that the synthesized derivatives inhibited &#x3b1;-amylase and &#x3b1;-glucosidase enzymes with IC50 values ranging from 3.65&#xa0;&#xb1;&#xa0;0.20&#xa0;&#x3bc;M to 32.15&#xa0;&#xb1;&#xa0;3.20&#xa0;&#x3bc;M on &#x3b1;-amylase and 5.92&#xa0;&#xb1;&#xa0;0.80&#xa0;&#x3bc;M to 35.60&#xa0;&#xb1;&#xa0;3.40&#xa0;&#x3bc;M on &#x3b1;-glucosidase, in contrast to the reference drug Acarbose (&#x3b1;-amylase IC50&#xa0;=&#xa0;8.25&#xa0;&#xb1;&#xa0;0.80&#xa0;&#x3bc;M; &#x3b1;-glucosidase IC50&#xa0;=&#xa0;10.75&#xa0;&#xb1;&#xa0;1.10&#xa0;&#x3bc;M). Among the series 9a-9f and 10a-10f, analogs 10&#xa0;f, 10b, 9b, and 9e displayed superior anti-diabetic activity compared to the reference drug Acarbose. The inhibitory activity of these conjugates can be attributed to their favorable and stable interactions with critical amino acid residues of targeted enzymes, as revealed through molecular docking analysis. ADMET predictions and drug-likeness evaluations showed favorable pharmacokinetic features, while DFT investigations revealed electronic insights related to bioactivity. Experimental outcomes and in silico support display that these potent Hydroxybenzothiazole-Linked Benzothiazole/Benzoxazole Conjugates were comparable to an existing diabetic mellitus inhibitor while conserving an acceptable safety profile, specifying potential for further therapeutic development and optimization against diabetic Mellitus.

Benzothiazoles

Gas chromatographic-mass spectrometric detection of trace amounts of organic compounds in the intravenous solution Infusio Darrowi.

A gas chromatographic-mass spectrometric procedure was employed to confirm the presence of trace amounts of organic compounds in the intravenous solution Infusio Darrowi. Organic contaminants in the solution analysed were concentrated by microextraction with n-pentane. The main compounds detected were 2,6-di-tert.-butyl-4-methylphenol, 2,6-di-tert.-butyl-4-ethylphenol, 2,6-di-tert.-butyl-4-methoxyphenol, benzothiazole, isomeric C9 alkyl phenols and di(n-butyl) phthalate. These impurities were leached from rubber stoppers during their sterilization into the intravenous solution at levels ranging ca. from 5 x 10(-6) to 5 x 10(-8) g/l.

Benzothiazoles

Reticulocyte quantification by flow cytometry, image analysis, and manual counting.

Reticulocyte counting by flow cytometry with thiazole orange was compared to manual or automated counting of new methylene blue stained blood smears. Forty-nine samples were compared for manual counting from randomly chosen clinical samples. Two hundred and eighty-nine samples from bone marrow transplant patients were compared during the period before and through chemo-irradiation and engraftment. The slopes of correlation plots were less than 1 when flow cytometric data were the dependent variable, suggesting that thiazole orange is less sensitive than new methylene blue. In a third study, 407 samples from bone marrow transplant patients were compared after increasing the thiazole orange concentration. The reticulocyte fluorescence distribution was divided into four groups of the brightest (youngest) 40, 60, 80, and 100% of reticulocytes. The slopes from regression analysis were 0.25, 0.49, 0.78, and 1.14, respectively. This demonstrates that thiazole orange is more sensitive than new methylene blue because the window of analysis includes an increased fraction of mature reticulocytes. In addition, the precision of each assay as measured. The rank order of precision from high to low was flow cytometry > image analysis >> manual counting.

Benzothiazoles