Biomaterial optimization in total disc arthroplasty.

Abstract

STUDY: Knowledge gained through the clinical history of total joint replacement materials combined with the current promise of new biomaterials provides improved guidelines for biomaterial selection in total disc arthroplasty. OBJECTIVES: The following will detail: 1) current biomaterials technology; 2) how current designs of total disc arthroplasty seek to optimize implant performance through judicious biomaterial selection; and 3) what technical obstacles and clinical concerns remain. METHODS: Metals and polymers remain the central material components of state-of-the-art total joint arthroplasties. Polymers provide low friction surfaces for articulating bearings and some degree of shock absorption. Metals provide appropriate material properties such as high strength, ductility, fracture toughness, hardness, corrosion resistance, formability, and biocompatibility necessary for use in load-bearing roles required total disc replacement. There are three principal metal alloys used in orthopaedics and particularly in total joint replacement: 1) titanium based alloys; 2) cobalt based alloys; and 3) stainless steel alloys. Alloy specific differences in strength, ductility, and hardness generally determine which of these three alloys is used for a particular application or implant component. RESULTS: Current designs. Two examples of current lumbar (Charitè and Prodisc) and cervical (Bryan and Prestige) disc replacements are compared. The similarities and differences in the biomaterials used for each demonstrate prevailing consensus and some idea of how to best optimize implant performance through biomaterial selection. CONCLUSION: The primary factors governing total disc arthroplasty biomaterials are similar to those of all total joint arthroplasties: generation of wear debris is the primary source of implant degradation, and the subsequent tissue reaction to such debris is the primary factor limiting the longevity of joint replacement prostheses. Particulate debris generated by wear, fretting, or fragmentation induces the formation of an inflammatory reaction, which at a certain point promotes a foreign-body granulation tissue response that has the ability to invade the bone-implant interface. This commonly results in progressive, local bone loss that threatens the fixation of both cemented and cementless devices alike. All metal alloy implants corrode in vivo. When severe, the degradative process may reduce structural integrity of the implant, and the release of corrosion products is potentially toxic to the host. The corrosion resistance of implant alloys is primarily due to the formation of passive oxide films to prevent significant electrochemical dissolution from taking place. The result of this knowledge is a consensus of opinion as to which materials are best suited for use in current total disc arthroplasty designs, where most total disc replacement designs incorporate cobalt-chromium-molybdenum alloy endplates articulating internally on a relatively soft polymeric core and externally coated with titanium or titanium alloy for enhanced bone fixation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nadim Hallab, Helmut D Link, Paul C McAfee. 2003-10-15. Biomaterial optimization in total disc arthroplasty.. https://doi.org/10.1097/01.brs.0000092214.87225.80

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electrochemical characterization of albumin protein on Ti-6AL-4V alloy immersed in a simulated plasma solution.

The effect of oxygen and albumin on the electrochemical behavior of a Ti-6Al-4V alloy immersed in a simulated inorganic plasma (SIP) solution was studied with a rotating-cylindrical electrode configuration to focus on the surface/electrolyte reactions. Potentiokinetic scans and electrochemical impedance spectroscopy have been used to characterize the interface by determining the passive current density and capacitance. For the polarization scans, an albumin addition of 37.7 mg/cm(3) to the SIP solution (oxygenated and unoxygenated) decreased the passive current density, indicating a lowering of the corrosive rate. The surface capacitance for the Ti-6Al-4V alloy immersed in a SIP solution averaged 13 microF/cm(2), which transformed after albumin addition (37.7 mg/cm(3)) from a potential independent behavior to the capacitance ranging from 23 to 6 microF/cm(2) with increasing potentials from -800 to 1500 mV(SCE), respectively, indicative of albumin adsorption. Within the same potential range and albumin addition to oxygenated solutions, the capacitances expanded slightly with a similar decreasing trend from 31 to 6 microF/cm(2), although the capacitance depicts an interaction between the hydrated passive film and the adsorbed albumin from -550 to 500 mV(SCE) in which the capacitance plateaued at 15 microF/cm(2). The hydrated porous oxide film results from the porous rutile layer reacting with H(2)O(2) formed as an intermediary component of oxygen reduction at the Ti-6Al-4V surface. The passive film-albumin interaction would affect the processing of titanium alloys in their surface preparation for biocompatibility, as well as determining the reactivity of titanium alloys to proteins.

Alloys↗

Fatigue-crack growth properties of thin-walled superelastic austenitic Nitinol tube for endovascular stents.

Over the past 10 years, the supereleastic nickel-titanium alloy Nitinol has found widespread application in the manufacture of small-scale biomedical devices, such as self-expanding endovascular stents. Although conventional stress/strain-life (S/N) analyses are invariably used as the primary method for design against fatigue loading and for predicting safe lifetimes, fracture mechanics-based methodologies provide a vital means of assessing the quantitative effect of defects on such lifetimes. Unfortunately, fracture mechanics studies on fatigue in Nitinol are scarce, and most results do not pertain to the (thin-walled tube) product forms that are typically used in the manufacture of endovascular stents. In the current work, we document the basic fatigue-crack growth properties of flattened thin-walled ( approximately 400 microm thick) Nitinol tubing in a 37 degrees C air environment. Crack-growth behavior is characterized over a wide range of growth rates ( approximately 6 orders of magnitude) and load ratios, that is, as a function of the alternating and maximum stress intensities, at 50 Hz. Limited experiments at both 5 and 50 Hz were also performed in 37 degrees C air and simulated body fluid to determine whether the cyclic frequency affects the fatigue behavior. Fatigue-crack growth-rate properties in such thin-walled Nitinol tube are found to be quite distinct from limited published data on other (mainly bulk) product forms of Nitinol, for example, bar and strip, both in terms of the relative fatigue thresholds and the variation in steady-state growth rates.

Alloys↗