PubMed Health⌕ Search

PubMed · 14579749

Optimizing stringency for expression microarrays.

Abstract

While several studies have reported methods to optimize expression microarray protocols, none have dealt directly with hybridization wash stringency. We designed a series of experiments to determine the optimal stringency conditions for microarray experiments, using reproducibility and magnitudes of log2 (test/reference) ratio values as measures of quality. Low-stringency wash conditions of cell line hybridizations led to nonspecific binding, resulting in increased intensities, decreased magnitude of ratios, and poor reproducibility. Relatively high-stringency wash conditions were found to give the best reproducibility and large magnitude ratio changes, although increasing the stringency beyond this point led to lower magnitude ratios and poorer reproducibility. The expression levels of the ERBB2 oncogene in the BT474 versus MCF7 cell lines showed that high-stringency wash conditions gave the best agreement with real-time quantitative PCR, although the magnitude of the changes by microarray was smaller than for real-time quantitative PCR. Analysis of a series of cell lines washed at the optimized stringency indicated that the rank order of relative expression levels for ERBB2 microarray clones agreed well with the rank order of ERBB2 levels, as measured by quantitative PCR. These results indicate that the optimization of stringency conditions will improve microarray reproducibility and give more representative expression values.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

James E Korkola, Anne L Estep, Sunanda Pejavar, Sandy DeVries, Ronald Jensen, Frederic M Waldman. 2003. Optimizing stringency for expression microarrays.. https://doi.org/10.2144/03354mt04

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Prostate MR imaging at high-field strength: evolution or revolution?

As 3 T MR scanners become more available, body imaging at high field strength is becoming the subject of intensive research. However, little has been published on prostate imaging at 3 T. Will high-field imaging dramatically increase our ability to depict and stage prostate cancer? This paper will address this question by reviewing the advantages and drawbacks of body imaging at 3 T and the current limitations of prostate imaging at 1.5 T, and by detailing the preliminary results of prostate 3 T MRI. Even if slight adjustments of imaging protocols are necessary for taking into account the changes in T1 and T2 relaxation times at 3 T, tissue contrast in T2-weighted (T2w) imaging seems similar at 1.5 T and 3 T. Therefore, significant improvement in cancer depiction in T2w imaging is not expected. However, increased spatial resolution due to increased signal-to-noise ratio (SNR) may improve the detection of minimal capsular invasion. Higher field strength should provide increased spectral and spatial resolution for spectroscopic imaging, but new pulse sequences will have to be designed for overcoming field inhomogeneities and citrate J-modulation issues. Finally, dynamic contrast-enhanced MRI is the method of imaging that is the most likely to benefit from the increased SNR, with a significantly better trade-off between temporal and spatial resolution.

Artifacts↗

Compensation for unknown acquisition delay caused by digital receiver without external synchronization in NMR and MRI.

The unknown acquisition delay problem caused by a digital receiver without external synchronization in NMR and MRI applications is discussed in detail. An effective procedure is suggested for overcoming the problem. The main features of the proposed method include minimal hardware modifications and highly efficient algorithms. It is important to note that this method does not rely on any special architecture for the digital receiver. To test the method, a digital receiver was implemented using a commercially available single-chip IC. Finally, the method was verified on a 0.3-T home-built MRI system. The experimental results show that the proposed method may be a useful tool for correcting the unknown acquisition delay arising from commercially available digital receivers without external synchronization in NMR and MRI.

Artifacts↗