PubMed Health⌕ Search

PubMed · 1458527

PTCA with side-by-side balloon using fixed guide wire systems: a potential alternative autoperfusion device--an in vitro study.

Abstract

The use of "hugging balloons" for the implementation of a coronary angioplasty is a well-known and much-written-about technique. It has not, on the other hand, ever been stressed that two inflated hugging balloons are not totally obstructive, leaving enough space, between the balloons and the arterial wall, for perfusion. The cross section of this free area can be as much as 12% of the total arterial cross section, when the side-by-side balloons are of a relatively similar size. Calculations show that similar total conduit cross sections are achieved when inflating either a 3.0 balloon or two 2.0 side-by-side balloons. An in vitro experiment compares how systems using 2.0 double balloons and a 3.0 autoperfusion balloon affect the distal flow of a 3 mm internal diameter conduit. A semi-rigid silastic tubing is perfused with a 5% glucose isotonic solution at various predetermined proximal pressure levels. Distal pressures and flows are measured at different stages: with no balloon, with deflated balloons, and with inflated balloons. Comparison shows that 1) the double balloon system offers little resistance to flow compared to the autoperfusion balloon; 2) this system's rate of perfusion run-off is hardly affected and is constantly better than with the autoperfusion balloon; 3) this difference is all the more marked, the lower the proximal perfusion. These results suggest that the use of a double balloon could, in some cases, provide an alternative solution to autoperfusion equipment. Further clinical studies are needed to test this hypothesis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J P Colle, N Delarche. 1992. PTCA with side-by-side balloon using fixed guide wire systems: a potential alternative autoperfusion device--an in vitro study.. https://doi.org/10.1002/ccd.1810270412

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stent fracture: an unusual cause of late restenosis after sirolimus-eluting stent placement.

Stent fracture is uncommon but may have consequences including restenosis. To date, stent fractures reported have been related to aggressive post dilation. We describe a case that involves fracture of a stent deployed to nominal pressure. Unlike most stent fractures reported that involve stent struts only our case demonstrated circumferential disruption with complete separation of the stent segments.

Angioplasty, Balloon, Coronary↗

Magnetic navigation system used successfully to cross a crushed stent in a bifurcation that failed with conventional wires.

Bifurcation lesions can be technically demanding to manage, and even in the era of drug eluting stents, their procedural success is variable. The use of the crush technique followed by "kissing" balloon postdilatation has been shown to improve the overall outcome. However, crossing the crushed stent is essential to allow performance of a final dilatation with "kissing" balloons and is regarded as the main Achilles' heel of this technique. In this report, we describe the first reported, planned procedure to use a magnetic navigation system to steer a wire through the crushed stent to use "kissing" balloons that had previously failed with conventional wires.

Angioplasty, Balloon, Coronary↗

On understanding the power of judgement in percutaneous coronary intervention.

AIM: Explain how research can advance the state-of the- practice in percutaneous coronary intervention (PCI). METHODS AND RESULTS: Identifying the success factors of PCI; identifying decision- making performance (power of judgement) as the factor that could be advanced faster than is currently the case; explaining why and how such advancement needs a different research approach than those currently pursued in medical research; presenting initial results of this approach in the form of a set of basic concepts (pivoting around risk) that are useful for describing the decision-making process during a PCI. CONCLUSION: Building a terminology (ontology) of PCI decision-making concepts and then eliciting expert knowledge about the decision-making process itself are promising ways of advancing the teachability of PCI and hence the state-of-the practice.

Angioplasty, Balloon, Coronary↗