PubMed Health⌕ Search

PubMed · 14596270

[Pulse oximetry and capnography].

Abstract

Noninvasive methods of monitoring are crucial in the management of intensive care patients, especially in the pediatric field. Pulse oxymetry measures arterial oxygen saturation in severely ill patients, allows oxygen requirements to be adjusted to the patient, reduces invasive gasometric studies and achieves continuous monitoring of the critically ill child. Motion and deficient tissular perfusion reduce the accuracy of the measured values, but more sophisticated pulse oximeters are more effective in preventing these artifacts. Capnometers are an excellent method of measuring end-tidal CO2 values in real time in intubated patients. Capnography produces a graphic curve of end-tidal CO2 while capnometry provides a numerical representation of this concentration. This technique is highly useful in the continuous monitoring of various respiratory problems and situations such as weaning or checking the correct placement of endotracheal cannulas.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F J Cambra Lasaosa, M Pons Odena. 2003. [Pulse oximetry and capnography].. https://doi.org/10.1016/s1695-4033(03)78176-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Sublingual capnometry: a non-invasive measure of microcirculatory dysfunction and tissue hypoxia.

With improvement in supportive care patients rarely die from their presenting illness but rather from its sequela, namely sequential multi-organ failure. Tissue hypoxia is believed to be the causation of multi-organ dysfunction syndrome (MODS). The expedient detection and correction of tissue hypoxia may therefore limit the development of MODS. The standard oxygenation and hemodynamic variables (blood pressure, arterial oxygenation, cardiac output) which are monitored in critically ill patients are 'upstream' markers and provide little information as to the adequacy of tissue oxygenation. Global 'downstream' markers such as mixed venous oxygen saturation and blood lactate are insensitive indicators of tissue hypoxia. Sublingual PCO(2) is a regional marker of microvascular perfusion and tissue hypoxia that holds great promise for the risk stratification and end-point of goal directed resuscitation in critically ill patients. This paper reviews the technology and application of sublingual PCO(2) monitoring.

Blood Gas Monitoring, Transcutaneous↗

Measurement of combined oximetry and cutaneous capnography during flexible bronchoscopy.

The aim of the present study was to assess the feasibility of measuring combined arterial oxygen saturation measured by pulse oximetry (Sp,O2) and cutaneous carbon dioxide tension (Pc,CO2) to monitor ventilation and quantify change in Pc,CO2 during bronchoscopy. Combined Sp,O2 and Pc,CO2 were measured at the ear lobe in 114 patients. In four patients, the ear-clip slipped and they were excluded. In total, 11 patients had artefacts with Sp,O2 recordings, thus, Sp,O2 was analysed in 99 patients. Spirometry data were available in 77 patients. Multivariate analysis of covariance and logistic regression were used for statistical analyses. Mean baseline Pc,CO2 was 4.78+/-1.06 kPa (36+/-8 mmHg) and mean rise in the Pc,CO2 during bronchoscopy was 1.26+/-0.70 kPa (9.5+/-5.3 mmHg), while mean Pc,CO2 at the end of bronchoscopy was 5.85+/-1.19 kPa (44+/-9 mmHg) . Baseline Pc,CO2 and the lowest Sp,O2 were significantly associated with peak Pc,CO2 and the change in Pc,CO2 during bronchoscopy. Risk of significant hypoxaemia (Sp,O2<or=90%) was lower for a higher baseline Sp,O2. Peak Pc,CO2 was directly associated with significant hypoxaemia. There was no significant association in the baseline Pc,CO2, peak Pc,CO2, baseline Sp,O2 or the lowest Sp,O2 comparing patients with and without chronic obstructive pulmonary disease. In conclusion, it is feasible to measure combined pulse oximetry and cutaneous carbon dioxide tension effectively to monitor ventilation during flexible bronchoscopy.

Blood Gas Monitoring, Transcutaneous↗

Transcutaneous carbon dioxide monitoring.

Technologies now exist that measure carbon dioxide levels transcutaneously. Rapid assessment of patients who have depressed ventilation or suspected sepsis can improve treatment decisions including the need for admission to the ICU and pulmonary artery catheterization.

Blood Gas Monitoring, Transcutaneous↗