PubMed Health⌕ Search

PubMed · 14606796

Placement of mineral trioxide aggregate using two different techniques.

Abstract

The purpose of this study was to determine if the adaptation of mineral trioxide aggregate (MTA) would differ when placed into simulated root canals of varying length when using two different placement and condensation methods. Hand condensation was compared to ultrasonic condensation. Eighty polyethylene tubes were divided into four groups of 20 tubes each. The tubes in the four groups were prepared to receive 3-, 5-, 7-, and 10-mm lengths of MTA respectively. Each group of 20 tubes was subdivided; 10 samples of each length had MTA placed and condensed by the hand method and the other 10 by the ultrasonic method. After condensation the samples were evaluated with a light microscope and radiographs for the degree of adaptation of the MTA to the tube walls and for the presence of voids within the MTA material itself. The results demonstrated an 80% agreement for findings between the light microscopy and radiographic evaluation. Hand condensation resulted in better adaptation to the tube walls and less voids than the ultrasonic method. There was no significant difference in the results for any of the four lengths of MTA placed by the hand method (p > 0.9). At this time hand condensation should be considered the preferred method for placement of MTA.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Anita Aminoshariae, Gary R Hartwell, Peter C Moon. 2003. Placement of mineral trioxide aggregate using two different techniques.. https://doi.org/10.1097/00004770-200310000-00017

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Layer-by-layer self-assembly aluminum Keggin ions/Prussian blue nanoparticles ultrathin films towards multifunctional sensing applications.

In this study we described the nanocomposites films of specially synthesized inorganic Prussian blue (PB) nanoparticles and polyoxocation Al(13) Keggin ions that possess the excellent sensing activities. Film fabrication using layer-by-layer (LBL) self-assembly technique was followed by electrochemical characterization. The assembled multilayer Al(13)/PB films as sensor devices for both the catalytic reduction of H(2)O(2) and detecting the change of relative humidity were also investigated. The sensitivity of the biosensor was 0.886 mA cm(-2)mM(-1), and about two orders of magnitude change in resistance was observed as the relative humidity increasing from 5 to 95%. Both sensors exhibited good reproducibility, wide linear range. The performance and multifunctional abilities of these nanocomposites promise potential applications in biosensors, environmental controlling system and biomedical devices.

Aluminum Compounds↗

A new binary compound for the production of 124I via the 124Te(p,n)124I reaction.

The binary compound, aluminum telluride (Al(2)Te(3)), was investigated as a target material for the production of (124)I by way of the (124)Te(p,n)(124)I reaction on a low-energy cyclotron. The high melting point and formation of a glassy matrix upon heating provided a stable target material at irradiations up to 20 microA of 11 MeV protons. The 87% tellurium mass fraction and 95% iodine separation yield led to significantly higher quantities of iodine compared to traditional TeO(2)/6%Al(2)O(3) admixtures. Radiochemical analysis of distilled samples using ion chromatography showed that the product remained in the iodide form while supported in weak buffer solutions. Stable Te impurities in the radioiodine product were less than 0.5 microg following purification by ion exchange chromatography. Average thick target yields of 229+/-18 microCi/microAh were achieved, and typical production runs at 18 microA for three hours yielded 12 mCi at the end-of-bombardment. Total losses of the target material after each irradiation and distillation cycle were approximately 2%.

Aluminum Compounds↗