An application framework for computer-aided patient positioning in radiation therapy.

Abstract

The importance of exact patient positioning in radiation therapy increases with the ongoing improvements in irradiation planning and treatment. Therefore, new ways to overcome precision limitations of current positioning methods in fractionated treatment have to be found. The Department of Medical Physics at the German Cancer Research Centre (DKFZ) follows different video-based approaches to increase repositioning precision. In this context, the modular software framework FIVE (Fast Integrated Video-based Environment) has been designed and implemented. It is both hardware- and platform-independent and supports merging position data by integrating various computer-aided patient positioning methods. A highly precise optical tracking system and several subtraction imaging techniques have been realized as modules to supply basic video-based repositioning techniques. This paper describes the common framework architecture, the main software modules and their interfaces. An object-oriented software engineering process has been applied using the UML, C + + and the Qt library. The significance of the current framework prototype for the application in patient positioning as well as the extension to further application areas will be discussed. Particularly in experimental research, where special system adjustments are often necessary, the open design of the software allows problem-oriented extensions and adaptations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Liebler, M Hub, C Sanner, W Schlegel. 2003. An application framework for computer-aided patient positioning in radiation therapy.. https://doi.org/10.1080/14639230310001613458

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Practical assessment of the display performance of radiology workstations.

The performance of 14 primary clinical display monitor workstations in use in the Radiology Department of a large acute NHS Trust was assessed using the methods and guidelines described by the American Association of Physicists in Medicine Task Group 18. Tests undertaken included the measurement of ambient light, display uniformity, luminance ratio, luminance response, maximum luminance and spatial resolution. Four display monitors failed to meet at least one of the test's guideline tolerances. In addition a number of display monitors were found to be operating at settings that might reduce their useful life span. These devices were either replaced or recalibrated by the installers, or were subject to local adjustment to ensure applicable standards were met. Consequently the study suggests that quality assurance testing of display monitors used for image reporting is necessary and valuable to ensure that images are viewed at an appropriate standard.

Computer Terminals↗