Antibodies to high-frequency antigens may decrease the quality of transfusion support: an observational study.

Abstract

BACKGROUND: There is only little information on the transfusion support of patients with antibodies to high-frequency RBC antigens. STUDY DESIGN AND METHODS: In cooperation with reference laboratories and transfusion services in Austria, Germany, and Switzerland, the transfusion support provided to hospitalized patients identified as having such antibodies was reviewed during a 20-month period. RESULTS: A total of 52 patients with antibodies to high-frequency antigens were treated in hospitals. Twenty-two of them received 104 units of antigen-negative RBCs. In 23 cases, a deviation from the standard transfusion policy (e.g., transfusion of antigen-incompatible units) occurred. The use of frozen or fresh units varied amongst the different countries but did not affect the rate of deviation from protocol. About 20 percent of all units were supplied internationally. Four antibody specificities, anti-Kpb, anti-Vel, anti-Lub, and anti-Yta, were identified in two-thirds of the patients. CONCLUSION: This survey indicated that transfusion support was unsatisfactory in about one-third of the hospitalized patients with antibodies to high-frequency antigens. Maintaining a rapidly accessible stock of just four types of rare blood units would ensure adequate transfusion support for most of these patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Axel Seltsam, Franz F Wagner, Abdulgabar Salama, Willy A Flegel. 2003. Antibodies to high-frequency antigens may decrease the quality of transfusion support: an observational study.. https://doi.org/10.1046/j.1537-2995.2003.00565.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Parathyroid hormone values obtained with immunometric assays depend on the amino-terminal antibody specificity].

Introduction of 2nd generation immunometric assays for the measurement of serum parathyroid hormone (PTH), turned them more available, simple and rapid. These methods, based on double identification of the PTH molecule, supposedly measure the intact, bioactive molecule, with the sequence 1-84. Recent works showed that they also measure forms with amino-terminal deletions, like the 7-84 form, which are not able to activate the traditional PTH receptor (PTH1R). Thus, an important practical aspect is the definition of the PTH forms measured by the immunometric assays, a fact that depends on the specificity of the antibodies employed. In this report we compare the results obtained with an in-house immunofluorometric assay that presents a cross-reactivity of 50% with the 7-84 PTH sequence, and two commercial 2nd generation assays, that react 100%. In a first study, 135 samples were measured using our assay and an electrochemiluminescent assay, resulting in a correlation coefficient of 0.961 (P<0.0001) and medians of 35.0 and 51.0 ng/L (P<0.0001). In a second study, 252 samples were analyzed using our assay and an immunochemiluminometric assay, resulting in a correlation of 0.883 (P<0.0001) and medians of 36.0 and 45.5 ng/L (P<0.0001). In both studies results obtained with the in-house assay were significantly lower, as expected by the specificity of the anti-amino-terminal antibody employed. Our data support the need of a precise description of the specificity of the amino-terminal antibodies employed in 2nd generation PTH assays in order to better compare results and define normal ranges.

Antibody Specificity↗

Detection of citrate synthase-reacting autoantibodies after heart transplantation: an epitope mapping study.

Autoimmune mechanisms play an important role in the pathogenesis of allograft vasculopathy following heart transplantation, but the autoantigens involved have been only sparsely studied. Citrate synthase (CS) enzyme is a conserved molecule, and, as an important mitochondrial autoantigen, it is protected by the "immunological homunculus". Tissue destruction and alteration of the immune regulatory mechanisms can induce pathological immune response against CS in other autoimmune diseases. In our present study we aimed to detect CS-specific autoantibodies in heart transplant patients, therefore, prospective, randomised clinical tests were conducted on 33 heart transplant patients and compared with 130 healthy blood donors. The level and isotype of CS antibodies were detected by simple binding indirect enzyme-linked immunosorbent assay (ELISA). The epitope specificities of the autoantibodies were measured on synthetic overlapping peptide sequences of CS enzyme by an indirect multi-pin ELISA method. Mainly IgM isotype CS autoantibodies were found in healthy controls, while IgG was found at higher levels and frequency (four-times higher) in heart transplant patients. Autoantibodies of IgG isotype recognise different epitopes than do autoantibodies of IgM isotype, even within the same group and individual. New epitope-specific IgG and IgM isotype autoantibodies appeared in heart transplant patients when compared with the controls. Our findings suggest a possible role of CS-specific autoantibodies in the pathomechanism of allograft vasculopathy.

Antibody Specificity↗

Identification and characterization of plasma membrane proteins that bind to microtubules in pollen tubes and generative cells of tobacco.

The organization and function of microtubules in plant cells are important in many developmental stages. Connections between microtubules and the endomembrane system of plant cells have been discovered by microscopy, but the molecular characteristics of these relationships are mostly unknown except for a few cases. Using two antibodies raised against microtubule-associated proteins (MAPs) from maize, we have identified two polypeptides that share properties of the MAP family in the pollen tube of Nicotiana tabacum. The two polypeptides (with an apparent Mr of 161 and 90 kDa) bind efficiently to animal and plant microtubules and are found in association with the cellular membranes of the pollen tube, from which they can be solubilized with a zwitterionic detergent. One of these proteins has been purified and shown to promote the assembly of tubulin and, to a lesser extent, the bundling of microtubules. Subcellular fractionation indicated that the two proteins are associated with the plasma membrane compartment. The two proteins are found to co-localize in situ with cortical microtubules in the vegetative cytoplasm of tobacco pollen tubes; co-localization is also evident in the generative cell. According to these data, both the 161 and 90 kDa polypeptides are likely to mediate the interactions between the plasma membrane and microtubules in pollen tubes. In addition, functional data indicate that these MAP-like proteins take part in the process of microtubule assembly and reorganization occurring during cell growth. The evidence that both proteins associate with different cellular compartments also suggests a broad-spectrum role in mediating the dynamic relationships between microtubules and plant cell membranes.

Antibody Specificity↗