Is all asthenopia the same?

Abstract

PURPOSE: Any of several conditions can cause asthenopia. The purpose of this study was to determine whether the particular sensations or their location vary dependent on the symptom-inducing condition. METHODS: Twenty subjects with good vision performed eight reading tasks in random order during different conditions. Each condition used different stimuli to induce asthenopia. The eight conditions were mixed astigmatism, close viewing distance, upward gaze, dry eyes, lens flipper, small font, glare, and flickering light. Subjects were asked to read until attaining a level of discomfort self-defined as "barely tolerable." After each task, subjects rated the magnitude of several symptom descriptors (burning, ache, strain, irritation, tearing, blurred vision, double vision, dryness, and headache) and their location. RESULTS: Analysis of variance with repeated measures was used to determine that all of the individual symptom sensation measures (except blur) were significantly related (p values ranged from 0.003 to <0.0001) to the inducing condition. Principal factor analysis with orthogonal varimax rotation was used to test symptom by condition relationships and determined two latent factors, designated external and internal symptom factors (ESF and ISF), that related symptoms to inducing condition. The ESF pattern comprises burning, irritation, tearing, and dryness located in the front and bottom of the eye. ESF is caused by holding the eyelid open, glare, up gaze, small font, and flickering. ESF seems highly related to dry-eye symptoms. The ISF pattern comprises ache, strain, and headache located behind the eyes. ISF is caused by the close viewing distance, lens flipper, and mixed astigmatism conditions and is likely related to accommodative and vergence stress. CONCLUSIONS: Symptom descriptors and locations were able to distinguish discomfort on the basis of causative condition. Results support two different symptom constellations and, hence, at least two different afferent pathways for symptoms of asthenopia.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

James E Sheedy, John N Hayes, Jon Engle. 2003. Is all asthenopia the same?. https://doi.org/10.1097/00006324-200311000-00008

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Conceptual model of human blur perception.

An empirically based, conceptual model of human blur perception is presented. It incorporates the concepts of blur detection and blur discrimination in depth, and across the central and peripheral retina, in two- and three-dimensional visual space. Key aspects of the model are its dynamic nature, predictability regarding the blur-based depth-ordering of objects, patterns of retinal defocus with far and near viewing, and interactions related to retinal defocus between the central and peripheral retina. Furthermore, a two-dimensional schematic representation of the blur-free region during near viewing is depicted in dioptric space. This model has implications with respect to accommodative control, depth perception, and refractive error development and progression.

Accommodation, Ocular↗

The effect of human in vivo accommodation on crystalline lens stability.

AIM: To determine the effect of human in vivo accommodation on the stability of the crystalline lens. METHODS: Using a dual Purkinje image (DPI) eyetracker, the phase-time difference and amplitudes of Purkinje images I (P(I)) and IV (P(1V)) were measured in 37 normal emmetropic subjects (34 women and 3 men; mean age 19.8, range 18-22 years) when they changed focus from 70 to 15 cm and simultaneously rotated their heads horizontally from side to side or made horizontal saccades between two targets 6.8 degrees apart. RESULTS: When the subjects changed focus from 70 to 15 cm and rotated their heads or made eye saccades, the phase-time difference between P(I) and P(IV) decreased. During saccades, the amplitude of both P(I) and P(IV) overshoots significantly increased with focus at 15 cm; however, their ratio (P(IV) overshoot amplitude/P(I) overshoot amplitude) significantly declined. CONCLUSIONS: The lens is stable during accommodation. The implications of these findings on the mechanism of accommodation are discussed.

Accommodation, Ocular↗

Synchrony dual-optic accommodating intraocular lens. Part 2: pilot clinical evaluation.

PURPOSE: To evaluate the clinical outcomes of an accommodating dual-optic intraocular lens (IOL). SETTING: Private practice and university centers. METHODS: A prospective noncomparative case series with retrospective control comprised 21 patients (26 eyes) scheduled for small-incision extracapsular cataract extraction by phacoemulsification with implantation of the Synchrony dual-optic accommodating IOL (Visiogen) (accommodating IOL group) and 10 patients who had small-incision extracapsular phacoemulsification with implantation of a monofocal, single-optic IOL at least 6 months previously (control group). Patients were examined 1, 3, 6, and 12 months after surgery. Defocus curves in the accommodating IOL group were compared with those in the control group. The main outcome measures were postoperative distance uncorrected and best corrected visual acuity; near uncorrected, distance corrected, and near corrected visual acuity; and accommodative range based on defocus curves. RESULTS: Twenty-four eyes were available at the 6-month follow-up visit. All eyes had best corrected distance visual acuity of 20/40 or better, and 19 eyes (79%) had an uncorrected distance visual acuity of 20/40 or better. Uncorrected near visual acuity was 20/40 or better in all eyes. With distance correction, 23 eyes (96%) had an acuity of 20/40 or better at near. Defocus curve analysis suggested a mean accommodative range of 3.22 diopters (D) +/- 0.88 (SD) (range 1.00 to 5.00 D) in the accommodating IOL group and 1.65 +/- 0.58 D in the control group (range 1.00 to 2.50 D) (P<.05). CONCLUSION: The Synchrony dual-optic IOL shows promise as an option to provide accommodative function in pseudophakic patients.

Accommodation, Ocular↗