[A novel method for sentinel lymph node mapping using magnetite].

Abstract

The detection rate of sentinel lymph nodes using isosulfan blue dye is too low for clinical use. Although exposure to radioactivity is reportedly minimal, special procedures are nonetheless required when a radioactive isotope is used as a tracer. Therefore, to eliminate the need for a radioactive tracer and to obtain a better detection rate than is currently obtained with isosulfan blue dye, we have developed a novel method that employs magnetite as the tracer. The tracer employed is ferumoxides, a colloidal superparamagnetic iron oxide of non-stoichiometric magnetite. The magnetic force within the lymph nodes was measured using a highly sensitive hand-held magnetometer ex vivo. The rate of detection of sentinel lymph nodes was 82% in non-small cell lung cancer. Intraoperative sentinel lymph node mapping using ferumoxides and a highly sensitive magnetometer is a safe, accurate, and sensitive way to detect sentinel lymph nodes. To detect sentinel lymph nodes in vivo, the magnetometer should be sterilized and the sensitivity of the magnetometer should be higher than that we used. Therefore now we are developing a more sensitive and sterilizable magnetometer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yoshihiro Minamiya, Jun-ichi Ogawa. 2003. [A novel method for sentinel lymph node mapping using magnetite].. https://pubmed.ncbi.nlm.nih.gov/14628710/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Type, severity, frequency and management of adverse reactions associated with ultrasound contrast agents: a systematic review and meta-analysis.

OBJECTIVES: This systematic review and meta-analysis are aimed at evaluating the incidence of adverse drug reactions (ADRs) following administration of clinically approved ultrasound contrast agents (UCAs) in adults and children, to assess risks in patients with cardiovascular disease and in pregnancy, and to evaluate the effectiveness of emergency management of severe ADRs. MATERIALS AND METHODS: A PRISMA 2020 systematic review was conducted searching PubMed, Scopus, and Embase. Two reviewers independently screened, extracted data, and assessed quality. Incidence estimates were pooled when feasible, stratified by age group, contrast agent, and administration route. RESULTS: Seventy-four studies encompassing >&#x2009;1 million adults and >&#x2009;36,000 children were included, contributing multiple analytic cohorts to the quantitative synthesis. Severe acute ADRs were extremely rare (6 and 16 cases per 100,000 in adults and children, respectively) and absent following endocavitary administration in children. Non-severe acute ADRs occurred in 11 and 8 cases per 10,000 adults and children, respectively. Delayed reactions were very rare (<&#x2009;1 case per million in adults). No significant safety differences emerged between UCA products. The incidence of ADRs in patients with cardiovascular disease was analogous to the general population. No ADRs were reported in pregnant women. Standard emergency management was effective in almost all serious cases, though rare fatalities occurred. CONCLUSION: UCAs show an excellent safety profile in adults and children, with very rare severe ADRs and few non-severe, typically self-limiting reactions. Strict adherence to recommended emergency management protocols mitigates the remaining risks, supporting safe use across a broad range of clinical indications. PROSPERO REGISTRATION: CRD42023432668. KEY POINTS: Question What is the incidence, type, and severity of acute and delayed ADRs associated with clinically approved UCAs across different patient populations? Findings Severe acute adverse reactions are very rare, and non-severe reactions are rare and self-limiting, with no significant safety differences between adults, children, or patients with cardiovascular disease. Clinical relevant UCAs show an excellent safety profile across populations. These findings support their safe clinical use as reliable alternatives to iodine-based and gadolinium-based contrast agents in routine diagnostic imaging.

Contrast Media↗

Magnetic resonance imaging of orbital tumors.

This contribution provides an overview of diseases of eye and orbit and their appearance on magnetic resonance imaging. In recent years the diagnosis of eye and orbit pathology has profited significantly from increasingly sophisticated technical developments in the field of tomographic methods. Due to the small size of the examination area the improvement in spatial resolution and soft tissue contrast leads to an increase in image quality. In most clinical questions concerning eye and orbit pathologies magnetic resonance imaging is superior to computed tomography and should be early performed.

Contrast Media↗

Multidetector CT of the kidney.

The technological development of multidetector CT offers new possibilities for better imaging of organic structures that can be used in diagnosis of the kidney. The thinner slices allow a better spatial resolution, and slice fusion allows improved contrast resolution. The isotropic voxel has been realized in the latest 64-channel scanners. The image quality of arbitrarily reconstructed planes has arrived at the image quality of the scan plane. Faster scanning allows studies in different contrast phases, which is helpful for better discrimination of benign or malignant lesions especially in the highly vascularized kidney. Different phases of contrast uptake can be differentiated (arterial, cortico-medullary, nephrographic, and excretory phase). Multidetector CT brings along the risk of increased dose due to thinner slice collimation and overranging phenomena. Indications for CT investigation of the kidney include urolithiasis, tumor diagnosis and staging, renal trauma, and vascular disease. Even in children, special indications for CT of the kidney remain in polytrauma and tumor staging. Multidetector CT of the kidney has become a very valuable tool in urology, but a careful protocol strategy is mandatory.

Contrast Media↗