PubMed Health⌕ Search

PubMed · 14646119

Overview and new developments in softer X-ray (2A < lambda < 5A) protein crystallography.

Abstract

New methodologies with synchrotron radiation and X-ray free electron lasers (XFELs) in structural biology are being developed. Recent trends in harnessing softer X-rays in protein crystallography for phase determination are described. These include reference to a data-collection test at 2.6 A wavelength with a lysozyme crystal on SRS station 7.2 (Helliwell, 1983) and also use of softer X-rays (2 A wavelength) to optimise f " at the xenon L1 absorption edge in the Single Isomorphous Replacement Optimised Anomalous Scattering ('SIROAS') structure determination of apocrustacyanin A1 with four, partially occupied, xenon atoms (Cianci et al., 2001; Chayen et al., 2000). The hand of the protein was determined using the f " enhanced sulphur anomalous signal from six disulphides in the protein dimer of 40 kDa. In a follow-up study the single wavelength xenon L1-edge f " optimised data set alone was used for phase determination and phase improvement by solvent flattening etc. (CCP4 DM) (Olczak et al., 2003). Auto-tracing of the protein was feasible but required additional diffraction data at higher resolution. This latter could be avoided in future by using improved tilted detector settings during use of softer X-rays, i.e. towards back-scattering recording (Helliwell, 2002). The Olczak et al. study has already led to optimisation of the new SRS beamline MPW MAD 10 (see www.nwsgc.ac.uk) firstly involving the thinning of the beryllium windows as much as possible and planning for a MAR Research tilted detector 'desk top beamline' geometry. Thus the use of softer, i.e. 2 to 3 A wavelength range, X-rays will allow optimisation of xenon and iodine L-edge f " and enhancing of sulphur f " signals for higher throughput protein crystallography. Softer X-rays utilisation in protein crystallography includes work done on SRS bending-magnet station 7.2 in the early 1980s by the author as station scientist (Helliwell, 1984). In the future development of XFELs these softer X-ray wavelengths could also be harnessed and relax the demands to some extent on the complexity and cost of an XFEL. Thus, by use of say 4 A XFEL radiation and use of a back-scattering geometry area detector the single molecule molecular transform could be sampled to a spatial resolution of 2 A, sufficient, in principle, for protein model refinement (Miao et al., 1999). Meanwhile, Miao et al. (2003) report the first experimental recording of the diffraction pattern from intact Escherichia coli bacteria using coherent X-rays, with a wavelength of 2 A, at a resolution of 30 nm and a real-space image constructed. The new single-particle X-ray diffraction-imaging era has commenced.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John R Helliwell. 2003-11-28. Overview and new developments in softer X-ray (2A < lambda < 5A) protein crystallography.. https://doi.org/10.1107/s0909049503024099

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Prediction of side-chain conformations on protein surfaces.

An approach is described that improves the prediction of the conformations of surface side chains in crystal structures, given the main-chain conformation of a protein. A key element of the methodology involves the use of the colony energy. This phenomenological term favors conformations found in frequently sampled regions, thereby approximating entropic effects and serving to smooth the potential energy surface. Use of the colony energy significantly improves prediction accuracy for surface side chains with little additional computational cost. Prediction accuracy was quantified as the percentage of side-chain dihedral angles predicted to be within 40 degrees of the angles measured by X-ray diffraction. Use of the colony energy in predictions for single side chains improved the prediction accuracy for chi(1) and chi(1+2) from 65 and 40% to 74 and 59%, respectively. Several other factors that affect prediction of surface side-chain conformations were also analyzed, including the extent of conformational sampling, details of the rotamer library employed, and accounting for the crystallographic environment. The prediction of conformations for polar residues on the surface was generally found to be more difficult than those for hydrophobic residues, except for polar residues participating in hydrogen bonds with other protein groups. For surface residues with hydrogen-bonded side chains, the prediction accuracy of chi(1) and chi(1+2) was 79 and 63%, respectively. For surface polar residues, in general (all side-chain prediction), the accuracy of chi(1) and chi(1+2) was only 73 and 56%, respectively. The most accurate results were obtained using the colony energy and an all-atom description that includes neighboring molecules in the crystal (protein chains and hetero atoms). Here, the accuracy of chi(1) and chi(1+2) predictions for surface side chains was 82 and 73%, respectively. The root mean square deviations obtained for hydrogen-bonding surface side chains were 1.64 and 1.81 A, with and without consideration of crystal packing effects, respectively.

Crystallography, X-Ray↗

Double-stranded cycles: toward C84's belt region.

The reactivity of the double-stranded hydrocarbon cycle with two ether bridges (1) toward iodotrimethylsilane (TMSI) was investigated in some detail. The carbon skeleton of cycle 1 resembles the belt region of a C84 fullerene which makes it a potential precursor to the long sought after fully aromatic derivative. Upon exposure to TMSI, cycle 1 undergoes a cascade of reactions which involve different states of iodination/reduction which ultimately lead to the hydrogenated cycle 5a, whose structure was proven by single-crystal X-ray analysis. A deeper insight into mechanistic aspects of this sequence of conversions was gained by performing the reaction under dry and wet conditions, whereby the latter involved both normal and deuterated water. With the help of detailed NMR correlation studies and DFT computations, all important aspects were clarified including an unexpected selective H/D exchange at the naphthalenic moieties.