PubMed Health⌕ Search

PubMed · 14646120

Recent developments in micro-diffraction on protein crystals.

Abstract

Protein crystallography micro-diffraction and micro small-angle X-ray scattering at a third-generation synchrotron radiation source undulator beamline both require a compromise on beam size and beam divergence. Micro small-angle X-ray scattering requires in addition an as-close-as-possible angular approach to the direct beam, which is mainly limited by the beam divergence at the sample position. Both techniques have been developed at the ESRF microfocus beamline in a complimentary way. The development of a dedicated microgoniometer in the frame of an EMBL/ESRF collaboration has revealed the potential of micro-diffraction for protein crystallography and is a step in the quest for user friendly instrumentation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Christian Riekel. 2003-11-28. Recent developments in micro-diffraction on protein crystals.. https://doi.org/10.1107/s090904950302541x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Are real-time displays of benefit in the singing studio? An exploratory study.

This article reports on an exploratory research project to evaluate the usefulness or otherwise of real-time visual feedback in the singing studio. The primary purpose of the work was not to optimize the technology for this application, but to work alongside teachers and students to study the impact of real-time visual feedback technology use on the students' learning experiences. An action research methodology was used to explore the benefit of real-time displays over an extended period. The experimental phase of the work was guided by a Liaison Panel of teachers and academics in the areas of singing, pedagogy, voice science, speech therapy, and linguistic science. Qualitative data were collected from eight students working with two professional singing teachers. The teachers and students acted as co-researchers under the action research paradigm. Teachers and students alike kept journals of their teaching and learning experiences. Singing lessons were observed regularly by the research team, coded for teacher and student behaviors, and all co-researchers were interviewed at the mid- and endpoint of the project. The use of technology had a positive impact on the learning process, and this is evidenced through case study data.

Equipment Design↗

Performance evaluation and testing of digital intra-oral radiographic systems.

Four digital intra-oral radiographic systems were tested and evaluated; three charge-coupled device (CCD) based systems from RVG, Visualix and Sidexis and a photostimulable phosphor (PSP) system from DenOptix. Image quality was assessed using three purpose-built phantoms to measure uniformity, low contrast detail detectability and signal-to-noise ratio (SNR). Limiting resolution was measured using a 20 lp mm(-1) bar pattern. Radiation output inaccuracies caused difficulties in achieving optimum doses for CCD systems. However, the accuracy was improved by using K-edge filters. SNR measurements proved to be a useful tool in assessing system performance. Each system has specific attributes: resolution was highest for the RVG system, the Visualix system measured the highest SNR and the lowest exposure settings were on the Sidexis system. Test methods and phantoms developed are suitable for acceptance testing and commissioning digital dental X-ray systems and for programming each system to produce an optimum level of image quality.

Equipment Design↗

A Faraday effect position sensor for interventional magnetic resonance imaging.

An optical sensor is presented which determines the position and one degree of orientation within a magnetic resonance tomograph. The sensor utilizes the Faraday effect to measure the local magnetic field, which is modulated by switching additional linear magnetic fields, the gradients. Existing methods for instrument localization during an interventional MR procedure often use electrically conducting structures at the instruments that can heat up excessively during MRI and are thus a significant danger for the patient. The proposed optical Faraday effect position sensor consists of non-magnetic and electrically non-conducting components only so that heating is avoided and the sensor could be applied safely even within the human body. With a non-magnetic prototype set-up, experiments were performed to demonstrate the possibility of measuring both the localization and the orientation in a magnetic resonance tomograph. In a 30 mT m(-1) gradient field, a localization uncertainty of 1.5 cm could be achieved.

Equipment Design↗