New approach to generalized two-dimensional correlation spectroscopy. IV: eigenvalue manipulation transformation (EMT) for partial attenuation of dominant factors.

Abstract

This paper extends our previous work on the potential of eigenvalue manipulating transformation (EMT) of a data matrix for spectral selectivity enhancement in two-dimensional (2D) correlation analysis. EMT operation by uniformly lowering the power of a set of eigenvalues associated with the original data exaggerates the information content of minor principal components and reduces that of major principal components. Thus, much more subtle differences of spectral behavior for each component are now highlighted. Similarly, the selective truncation of dominant principal component (PC) factors to bring up the subtle contributions of minor factors is also considered. The EMT-reconstructed data matrix where power parameter m is negative greatly reduces the contribution of the first PC. Hybrid models for the attenuation of the contribution of the first PC are discussed. Synchronous 2D correlation spectra from PC1-attenuated data matrix A** obtained by varying the value of the attenuation parameter k show a much more profound effect than asynchronous 2D correlation spectra. As the value of k is increased, features of 2D correlation spectra start looking very much like those from the principle component analysis (PCA)-reconstructed data with only the second and third PCs and from the EMT-reconstructed data matrix where the power parameter m is negative.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Young Mee Jung, Seung Bin Kim, Isao Noda. 2003. New approach to generalized two-dimensional correlation spectroscopy. IV: eigenvalue manipulation transformation (EMT) for partial attenuation of dominant factors.. https://doi.org/10.1366/000370203322102951

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.