PubMed Health⌕ Search

PubMed · 14658692

Error analysis for estimation of trace vapor concentration pathlength in stack plumes.

Abstract

Near-infrared hyperspectral imaging is finding utility in remote sensing applications such as detection and quantification of chemical vapor effluents in stack plumes. Optimizing the sensing system or quantification algorithms is difficult because reference images are rarely well characterized. The present work uses a radiance model for a down-looking scene and a detailed noise model for dispersive and Fourier transform spectrometers to generate well-characterized synthetic data. These data were used with a classical least-squares-based estimator in an error analysis to obtain estimates of different sources of concentration-pathlength quantification error in the remote sensing problem. Contributions to the overall quantification error were the sum of individual error terms related to estimating the background, atmospheric corrections, plume temperature, and instrument signal-to-noise ratio. It was found that the quantification error depended strongly on errors in the background estimate and second-most on instrument signal-to-noise ratio. Decreases in net analyte signal (e.g., due to low analyte absorbance or increasing the number of analytes in the plume) led to increases in the quantification error as expected. These observations have implications on instrument design and strategies for quantification. The outlined approach could be used to estimate detection limits or perform variable selection for given sensing problems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Neal B Gallagher, Barry M Wise, David M Sheen. 2003. Error analysis for estimation of trace vapor concentration pathlength in stack plumes.. https://doi.org/10.1366/000370203322005283

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Modeling of local dynamic behavior of phenol degradation in an internal loop airlift bioreactor by yeast Candida tropicalis.

A coupled computational fluid dynamic (CFD) model, combining hydrodynamics with biochemical reactions, was developed to simulate the local transient flow patterns and the dynamic behaviors of cell growth and phenol biodegradation by yeast Candida tropicalis in an internal loop airlift reactor (ILALR). To validate this proposed model effectively, the simulated local hydrodynamic characteristics of the gas-mineral salt medium solution (gas-liquid) two-phase system, at a phenol concentration of 1,200 mg L(-1) and no presence of cells, was experimentally investigated in the ILALR using laser Doppler anemometer (LDA) measurements and conductivity probe. Furthermore, the validation of the simulated phenol biodegradation behavior by C. tropicalis at different initial concentrations of phenol and cell was also carried out in the ILALR. The time-averaged and transient results of the model simulations illustrated a satisfactory agreement with the experimental data. Finally, the local instantaneous flow and phenol biodegradation features, including gas holdup, gas velocity, liquid velocity, cell concentration, and phenol concentration inside the ILALR were successfully predicted by the proposed model.

Air Movements↗

Ground laser remote sensing measurements of a Saharan dust outbreak in Central Spain. Influence on PM10 concentrations in the lower and upper Spanish plateaus.

This paper presents the hourly evolution of a severe Saharan dust outbreak, (SDO), affecting Central Spain over July 23-24, 2004 measured with a laser remote sensing device at a location close to the Guadarrama mountain range foothills and its impact on PM10 levels (particles with an aerodynamic diameter below 10 microm) recorded at four contrasting monitoring stations located in the upper and lower Spanish plateau, some 170km apart. During the period of study the Saharan dust layer, (SDL), presented significant hourly variability in height (3600-1500m), depth (1500-700m) and aerosol dust loading (extinction coefficient, EC, 0.22-1.28km(-1)). Overnight layering was generally observed whereas a well mixed layer prevailed in the afternoon. The (SDO) impact on the lower levels took place approximately 12h after the (SDL) was initially observed and triggered by a descending dust enriched, evidencing the important role of subsidence over the presence of dust in lower altitudes. During the event, PM10 levels at all the stations exceeded EU air quality daily mean standards, 50 microgm(-3), on 2-4days. The maximum values ranged from 185 to 245 microgm(-3) depending on the monitoring station. The impact on PM10 spread from 2days in the upper plateau to 3-4 in the lower plateau, in agreement with the geographical location of the monitoring stations with respect to the southwest origin of the intrusion. The impact was even more dramatic on PM10 hourly concentrations, leading to maximum hourly peaks ranging from 322 to 598 microgm(-3) again depending on the monitoring station. Correlations between EC vertical profiles and PM10 hourly concentrations at the monitoring stations showed the great influence of the (SDO) on surface concentrations. The best linear fits corresponded to the extinction coefficients in the lower altitudes (close to the lower range of the device 500-650m), EC2, yielding satisfactory correlation coefficients ranging from 0.68 to 0.71. The low variability of the slope of each individual linear fit, 19.2%, shows the similar impact of (SDO) on the PM10 hourly concentrations recorded in the area under study.

Air Movements↗

Characterization of gas/particle concentrations and partitioning of polychlorinated biphenyls (PCBs) measured in an urban site of Turkey.

Air concentrations of polychlorinated biphenyls (PCBs) in both gas and particle phases were measured in an urban site (BUTAL-Merinos) of the city of Bursa, Turkey between August 2004 and May 2005. The mean of total (particle+gas) PCB concentrations was about 491.8+/-189.4pg/m(3). The main contributors for PCBs in the sampling site were the local sources and long-range atmospheric transport supported by back trajectory analysis. Lower molecular weight PCB congeners generally dominated in the samples. The particle phase of the measured PCBs accounted for 15% of the total PCB concentrations. Gas/particle distribution was investigated using different approaches such as log K(P)-log P(L)(o), log K(P)-log K(OA) and the Junge-Pankow model. Regression analysis among log K(P), log P(L)(o) and log K(OA) exhibited significant correlation at p<0.05. Correlation between PCB homologs and meteorological parameters was formed to investigate the possible relationships.

Air Movements↗