PubMed Health⌕ Search

PubMed · 14669802

Composting under controlled conditions.

Abstract

Three cylindrical reactors, each with a working capacity of approximately 200 litres, were used to investigate composting. The process was optimised and conditions were controlled so that composting on a laboratory-scale thermally resembled that occurring in the core of large open heaps. A baseline flow of humidified air aerated the reactors in five-minute bursts. The reactors operated as closed systems with facilities to analyse the composition of the off-gas for ammonia, oxygen and carbon dioxide. Temperature was used to monitor the progress of the process. Heat loss from the reactor surface was compensated for with an external heat source. A basic model of radial conductive heat losses showed that 53 watts per square-metre would be the maximum heat flux needed to keep the temperature difference across the reactor to within a degree when running at 60 degrees C. A heating cable was used, which could supply 150 watts per square-metre, and the radial temperature difference was reduced to within a degree in more than 60% of the recorded temperatures in the case studies presented. The temperature of the composting material was held at 60 degrees C using a high flow rate 'cooling' aeration with temperature feedback. This, however, led to a mean vertical temperature difference of at least 10 degrees C. The aeration strategy resulted in a well-aerated material, which favoured aerobic microbial activity and the temperature increased as a result of the internally generated heat associated with composting. Three-quarters of the ammonia was emitted in the first week.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Cronjé, C Turner, A Williams, A Barker, S Guy. 2003. Composting under controlled conditions.. https://doi.org/10.1080/09593330309385664

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Short-cut nitrification of domestic wastewater in a pilot-scale A/O nitrogen removal plant.

The feasibility of nitrite accumulation in a pilot-scale A/O (anoxic/oxic) nitrogen removal plant treating domestic wastewater was investigated at various dissolved oxygen (DO) concentrations and pH levels. The results showed that the pH was not a useful operational parameter to realize nitrite accumulation. Significant nitrite accumulation was observed at the low DO concentration range of 0.3-0.8 mg/l and the maximum nitrite accumulation ratio of about 90% occurred at a DO concentration of 0.6 mg/l. This suggests a reduction of 22% in the oxygen consumption, and therefore a considerable saving in aeration. However, the nitrite accumulation was destroyed at the high DO concentration and the resumption was very slow. In addition, the average ammonia removal efficiency reached as high as 93% at the low DO level. Moreover, experimental results indicated that nitrogen could be removed by simultaneous nitrification and denitrification (SND) via nitrite in the aerobic zones at the low DO concentration, with the efficiency of 6-12%.

Bacteria, Aerobic↗

Reactivation of aerobic and anaerobic ammonium oxidizers in OLAND biomass after long-term storage.

The biomass of an oxygen-limited autotrophic nitrification/denitrification (OLAND) biofilm reactor was preserved in various ways to find a storage method for both aerobic and anaerobic ammonium-oxidizing bacteria (AerAOB and AnAOB). Storage occurred at -20 degrees C with and without glycerol as cryoprotectant and at 4 and 20 degrees C with and without nitrate as redox buffer. After 2 and 5 months, reactivation of AerAOB and AnAOB was achieved with the biomass stored at 4 degrees C with and without nitrate and at 20 degrees C with nitrate. Moreover, the presence of the AerAOB and AnAOB was confirmed with fluorescent in situ hybridization (FISH). Preservation in a nitrate environment resulted in a lag phase for the AnAOB reactivation. The supplied nitrate was denitrified during storage, and a real-time polymerase chain reaction with nitrifying and denitrifying genes allowed to estimate that at least 1.0 to 6.0% of the OLAND biofilm consisted of denitrifiers. It was concluded that reactivation after long-term storage is possible and that preservation at 4 degrees C without nitrate addition is the recommended storage technique. The possibility to store OLAND biomass will facilitate research on AnAOB and can overcome larger-scale start-up and inhibition problems of novel nitrogen processes involving AnAOB.

Bacteria, Aerobic↗

Decontamination of rough titanium surfaces with diode lasers: microbiological findings on in vivo grown biofilms.

OBJECTIVES: The bactericidal efficacy of diode lasers has already been demonstrated in vitro. We investigated the reduction of aerobe bacteria - colonizing rough titanium samples in biofilms intraorally grown - by diode lasers of different wave lengths. MATERIAL AND METHODS: Twenty-two volunteers participated in the trial. They were fitted for 10 days with custom-made intraoral plastic splints carrying titanium sleeves. A part of the sleeves was then irradiated with diode lasers in different modes. The other part remained non-irradiated and served as control. Directly after irradiation, the sleeves were swabbed and the gained bacteria were first examined microscopically and then were cultured under aerobic conditions. RESULTS: The bacteria in the controls and in the treated samples were quantified. A comparison with the controls revealed a marked overall reduction of bacterial colonization in all irradiated sleeves. Continuous irradiation for 20 s reduced bacteria counts by 99.67% at 810 nm and 99.58% at 980 nm. Repeating the 20 s exposure five times reduced counts by 99.98% at 810 nm and by 99.39% at 980 nm. A 98.86% reduction was seen after irradiation in pulsed mode. A further analysis in respect of different isolated bacteria revealed that the streptococci group was reduced by 99.29-99.99%, while the staphylococci group was reduced to a lesser extent in the range 94.67-99.99%. CONCLUSION: The results are of clinical relevance. In comparison with the mean bacterial counts of the untreated samples, all irradiation programs studied in this investigation reduced mean bacterial colonization in a biofilm on intraoral rough titanium surfaces by more than 98%. The actual extent of reduction was dependent on the bacteria species as well as on the irradiation mode.

Bacteria, Aerobic↗