Stable-isotope dimethyl labeling for quantitative proteomics.

Abstract

In this paper, we report a novel, stable-isotope labeling strategy for quantitative proteomics that uses a simple reagent, formaldehyde, to globally label the N-terminus and epsilon-amino group of Lys through reductive amination. This labeling strategy produces peaks differing by 28 mass units for each derivatized site relative to its nonderivatized counterpart and 4 mass units for each derivatized isotopic pair. This labeling reaction is fast (less than 5 min) and complete without any detectable byproducts based on the analysis of MALDI and LC/ESI-MS/MS spectra of both derivatized and nonderivatized peptide standards and tryptic peptides of hemoglobin molecules. The intensity of the a(1) and y(n-1) ions produced, which were not detectable from most of the nonderivatized fragments, was substantially enhanced upon labeling. We further tested the method based on the analysis of an isotopic pair of peptide standards and a pair of defined protein mixtures with known H/D ratios. Using LC/MS for quantification and LC/MS/MS for peptide sequencing, the results show a negligible isotopic effect, a good mass resolution between the isotopic pair, and a good correlation between the experimental and theoretical data (errors 0-4%). The relative standard deviation of H/D values calculated from peptides deduced from the same protein are less than 13%. The applicability of the method for quantitative protein profiling was also explored by analyzing changes in nuclear protein abundance in an immortalized E7 cell with and without arsenic treatment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jue-Liang Hsu, Sheng-Yu Huang, Nan-Haw Chow, Shu-Hui Chen. 2003-12-15. Stable-isotope dimethyl labeling for quantitative proteomics.. https://doi.org/10.1021/ac0348625

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Directed reductive amination of beta-hydroxy-ketones: convergent assembly of the ritonavir/lopinavir core.

An efficient procedure for the directed reductive amination of beta-hydroxy-ketones (3) for the stereoselective preparation of 1,3-syn-amino alcohols (6) is reported. The operationally simple protocol uses Ti(iOPr)4 for coordination of the intermediate imino alcohol (5) and PMHS as the reducing agent. The method was expanded to an asymmetric aldol reductive amination sequence to allow a highly convergent synthesis of the hydroxy-amine core of the HIV-protease inhibitors ritonavir and lopinavir. [reaction: see text].

Amination↗

Effect of silica nanoparticles with different sizes on the catalytic activity of glucose oxidase.

In this work we present a strategy for the covalent immobilization of periodate oxidized glucose oxidase (IO(4)(-) - GOx) to aminated silica nanoparticles (ASNPs) modified on gold electrodes. Silica nanoparticles greatly enhanced the catalytic ability of GOx toward the oxidation of glucose and improved the electron transfer between the GOx and the electrode surface. ASNPs of varying size--that is 100, 80, 60, and 30 nm--were prepared, and they were used to fabricate biosensors. Electrochemical impedance spectroscopy (EIS) of ferrocyanide followed the assembly process and verified the successful immobilization of IO(4)(-) - GOx on ASNPs modified on gold electrodes. From the analysis of catalytic signals of biosensors using different sizes of ASNPs under the same conditions, the surface concentration of electrically wired enzyme (Gamma (ET)) was estimated and was found to increase with decreasing ASNPs size. Therefore, the sensitivity of biosensors using smaller ASNPs was higher than that using larger particles. Specifically, we utilized the ASNPs with optimal size (30 nm) to fabricate the glucose biosensor. The resulting electrodes showed a wide linear response to glucose at least to 6 mM and reached 95% of the steady-state current in less than 4 s with a sensitivity of 5.02 microA mM(-1) cm(-2) and a detection limit of 0.01 mM. The biosensor also showed excellent stability and good reproducibility.

Amination↗