PubMed Health⌕ Search

PubMed · 14671579

[Cochlear implantation and vestibular function].

Abstract

To determine the risk of injuring a peripheral part of the vestibular analyzer in usage of an intracochlear implant in patients with varying deafness, the author compared her data and data from other clinics making examinations according to similar methods: implantation was conducted using multichannel intracochlear electrode, the program of otoneurological examination employed the caloric test, the patients were examined before and after the operation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N V Al'pidovskaia. 2003. [Cochlear implantation and vestibular function].. https://pubmed.ncbi.nlm.nih.gov/14671579/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Retrofacial approach of cochlear implantation in inner ear malformation with aberrant facial nerve: a case report.

Cochlear implantation is regarded as a safe surgery for young children with minimal complications. However, inner ear malformations and aberrant course of facial nerves may impede electrode insertion via the round window approach and increase the risk of iatrogenic facial nerve injury. We report a case of cochlear incomplete partition in a patient with anomalous facial nerve anatomy. The anterior and inferior displacement of the facial nerve obscured the round window. A retrofacial approach was used to expose the round window and the electrode was inserted successfully. No surgical complications were found postoperatively, and the child showed significant improvement in speech perception. As the course of the aberrant facial nerve is difficult to track preoperatively, surgeons should proceed with caution to reduce the risk of facial nerve injury during the operation.

Cochlear Implantation↗

Revision cochlear implantation for facial nerve stimulation in otosclerosis.

OBJECTIVE: To find if patients experiencing postsurgical facial nerve stimulation caused by underlying disease process (ie, otosclerosis) can improve their hearing performance with their cochlear implant by reimplantation and by an optimal programming strategy. DESIGN: Retrospective analysis. SETTING: Academic tertiary referral center. PATIENTS: Two cochlear otosclerosis patients with resistant facial nerve stimulation (FNS). Both patients were initially implanted with Nucleus 22 devices (Cochlear Corporation, Englewood, Colo) and they developed FNS after a period of use. Owing to the decreasing number of active electrodes, concurrent decreases in speech understanding occurred. INTERVENTIONS: Various programming approaches were used to address the FNS. Both subjects ultimately received Nucleus 24 devices. One was reimplanted in the same ear, and the other was implanted in the opposite ear. Both have been followed up for 8 months following the reimplantation. MAIN OUTCOME MEASURES: Cochlear implant programming levels, cochlear implant performance, and facial nerve stimulation. RESULTS: The FNS was managed for more than 3 years through optimized programming. However, the FNS progressed until performance dropped below acceptable levels. Reimplantation was believed to be the only option for improvement. After reimplantation and programming, both subjects showed immediate improvement in speech discrimination. One user increased his consonant-nucleus-consonant word score from 12% preoperatively to 42%, and the other's performance increased from 0% to 86%. CONCLUSIONS: Our results suggest that having more programming options with newer devices is critical in otosclerotic or ossified users who experience FNS. Also, reimplantation may be a useful tool to improve performance.

Cochlear Implantation↗

[Paediatric cochlear implantation in the first year of life: preliminary results].

BACKGROUND: The success of cochlear implants in children was followed by a stepwise reduction in age at time of surgery. As a result of newborn hearing-screening (NHS) and the reliable audiologic diagnostic procedure, the question is raised as to whether an implantation before the age of 1 year is effective and safe in terms of surgery and rehabilitation. METHOD AND PATIENTS: This retrospective study included 27 children implanted before the age of 1 year (Gr. 1) and 89 children implanted between the age of 1 and 2 years (Gr. 2). Patient related data were analysed for individual history, surgery, rehabilitation and speech understanding. RESULTS: The incidence of complications was not increased in Gr. 1. The fitting of a speech processor was effective and uneventful in all children. The development of hearing and speech understanding showed better results after 2 years in Gr. 1. This development is more obvious for absolute age and not to rehabilitation time. CONCLUSION: In order to achieve an optimal timing for the development of speech understanding, cochlear implantation should be performed before the age of 2 years. This study revealed no additional risks for children in Gr. 1, but the development of speech understanding was better. As a consequence, cochlear implantation should be considered for very young children with an identified bilateral profound hearing loss.

Cochlear Implantation↗