PubMed Health⌕ Search

PubMed · 14672166

A spiking neuron model: applications and learning.

Abstract

This paper presents a biologically inspired, hardware-realisable spiking neuron model, which we call the Temporal Noisy-Leaky Integrator (TNLI). The dynamic applications of the model as well as its applications in Computational Neuroscience are demonstrated and a learning algorithm based on postsynaptic delays is proposed. The TNLI incorporates temporal dynamics at the neuron level by modelling both the temporal summation of dendritic postsynaptic currents which have controlled delay and duration and the decay of the somatic potential due to its membrane leak. Moreover, the TNLI models the stochastic neurotransmitter release by real neuron synapses (with probabilistic RAMs at each input) and the firing times including the refractory period and action potential repolarisation. The temporal features of the TNLI make it suitable for use in dynamic time-dependent tasks like its application as a motion and velocity detector system presented in this paper. This is done by modelling the experimental velocity selectivity curve of the motion sensitive H1 neuron of the visual system of the fly. This application of the TNLI indicates its potential applications in artificial vision systems for robots. It is also demonstrated that Hebbian-based learning can be applied in the TNLI for postsynaptic delay training based on coincidence detection, in such a way that an arbitrary temporal pattern can be detected and recognised. The paper also demonstrates that the TNLI can be used to control the firing variability through inhibition; with 80% inhibition to concurrent excitation, firing at high rates is nearly consistent with a Poisson-type firing variability observed in cortical neurons. It is also shown with the TNLI, that the gain of the neuron (slope of its transfer function) can be controlled by the balance between inhibition and excitation, the gain being a decreasing function of the proportion of inhibitory inputs. Finally, in the case of perfect balance between inhibition and excitation, i.e. where the average input current is zero, the neuron can still fire as a result of membrane potential fluctuations. The firing rate is then determined by the average input firing rate. Overall this work illustrates how a hardware-realisable neuron model can capitalise on the unique computational capabilities of biological neurons.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chris Christodoulou, Guido Bugmann, Trevor G Clarkson. 2002. A spiking neuron model: applications and learning.. https://doi.org/10.1016/s0893-6080(02)00034-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A user-friendly PC-based data acquisition and analysis system for respirometric investigations.

We have developed an easy-to-use computer-based system for recording, displaying, storing and analyzing signals generated by Clark-type oxygen electrodes. A user-friendly interface of Windows-based program BioMed significantly increases the productivity of investigations. It allows to process, control, present and archive the experimental data in real time. A 12-bit analog-to-digital-converter, analog and digital filters, a possibility to zoom the obtained respiratory curves and calculation of the respiration rates by a linear regression method increase the resolution of the estimated oxygen consumption rates. The new system enables to register even small changes, such as 3-5 ngatoms O/min, in respiration rates of biological objects -- enzymes, mitochondria and permeabilized muscle fibers. The system has been developed and is regularly used for the respirometric investigations at the Laboratory of Biochemistry, Institute for Biomedical Research, Kaunas University of Medicine.

Analog-Digital Conversion↗

Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation.

A novel optical frequency-domain imaging system is demonstrated that employs a passive optical demodulation circuit and a chirped digital acquisition clock derived from a voltage-controlled oscillator. The demodulation circuit allows the separation of signals from positive and negative depths to better than 50 dB, thereby eliminating depth degeneracy and doubling the imaging depth range. Our system design is compatible with dual-balanced and polarization-diverse detection, important techniques in the practical biomedical application of optical frequency-domain imaging.

Analog-Digital Conversion↗