PubMed Health⌕ Search

PubMed · 14673653

Optical acceleration cancellation: a viable interception strategy?

Abstract

Interception of fly balls requires active locomotion toward the point where catching can take place; as a result, the visual information guiding interception is affected by the catcher's own movement. The only interception theory currently available for a catcher standing in the plane of motion of the ball is Optical Acceleration Cancellation (OAC); in this strategy, the pseudo-optical variable "optical acceleration" (OA), if nonzero, specifies how the catcher should adjust his current velocity. We formulate a precise implementation of OAC where the catcher strives to maintain OA zero at all times and analyze its implications in terms of the catcher's interception behavior for different ball trajectories under air-friction-free, low-friction, and friction-dominated conditions. We conclude that the point in the ball trajectory where first visual contact (FVC) takes place determines to a large extent the ensuing interception behavior of the catcher. Conventional trajectories (FVC slightly above eye level, ball coming toward the catcher) result in fast acceleration to a constant velocity and successful interception. Trajectories with FVC below eye level typically result in unsatisfactory behavior of the catcher, who runs away from rather than toward the point of interception. In addition, ball trajectories are identified for which the OA equals zero even though the catcher is not on an interception course.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L A Rozendaal, A J Knoek van Soest. 2003-11-18. Optical acceleration cancellation: a viable interception strategy?. https://doi.org/10.1007/s00422-002-0393-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Photodissociation at 193 nm of some singly protonated peptides and proteins with m/z 2000-9000 using a tandem time-of-flight mass spectrometer equipped with a second source for delayed extraction/post-acceleration of product ions.

A tandem time-of-flight mass spectrometer was built for photodissociation (PD) of singly protonated peptides and small proteins generated by matrix-assisted laser desorption/ionization. PD was performed in a second source after deceleration of precursor ions. The delayed extraction/post-acceleration scheme was used for the product ions. For the PD at 193 nm of small singly protonated peptides, the present instrument showed much better sensitivity and resolution for product ions than the previous one (Moon JH, Yoon SH, Kim MS, Bull. Korean Chem. Soc. 2005; 26: 763) even though the overall spectral patterns obtained with the two instruments were similar. The present instrument was inferior in precursor ion selection and background noise level. PD was achieved for precursor ions as large as the singly protonated ubiquitin (m/z 8560.63), indicating that the photoexcitation is capable of supplying a sufficient amount of internal energy to dissociate large singly protonated proteins. As the precursor ion m/z increased, however, product ion signals deteriorated rather rapidly. As in the PD of small peptide ions with m/z around 1000, the types of the product ions generated from singly protonated peptides with m/z in the range 2000-4000 were mostly determined by the positions of arginine residues. Namely, a(n) and d(n) ions dominated when an arginine residue(s) was near the N-terminus while v(n), w(n), x(n) and y(n) dominated when the same residue(s) was near the C-terminus. In addition, d(n), v(n) and w(n) ions were generated according to the correlation rules previously observed in the collisionally activated dissociation. Isoleucine and leucine isomers could be easily distinguished based on the w(n) and d(n) ions.

Acceleration↗

Consequences of a cross slope on wheelchair handrim biomechanics.

OBJECTIVE: To test the hypothesis that pushing on a cross slope leads to increased handrim loading compared with that found on a level surface. DESIGN: Case series. SETTING: Biomechanics laboratory. PARTICIPANTS: Twenty-six manual wheelchair users. INTERVENTION: Subjects pushed their own wheelchairs on a research treadmill set to level, 3 degrees , and 6 degrees cross slopes. Propulsion speed was self-selected for each cross-slope condition. Handrim biomechanics were measured for the downhill wheel, using an instrumented wheelchair wheel and a motion capture system. MAIN OUTCOME MEASURES: Speed, peak kinetics (force, rate of loading, torque), push angle, cadence, push distance, and power output were averaged over a 20-push set for each subject and each cross-slope condition. Outcomes were compared across cross slopes using a repeated-measures analysis of variance. RESULTS: Push angle and cadence were unaffected by cross slope. A trend of decreasing self-selected speeds with increasing cross slope was not significant. There were considerable increases in the peak kinetic measures, with the axial moment increasing by a factor of 1.8 on the 6 degrees cross slope (P=.000). More pushes were required to cover the same distance when on a cross slope (P<.034). The power required for propulsion increased by a factor of 2.3 on the 6 degrees cross slope (P=.000). CONCLUSIONS: Users must push harder when on a cross slope. This increased loading is borne by the users' arms, which are at risk for overuse injuries. Exposure to biomechanic loading can be reduced by avoiding cross slopes when possible.

Acceleration↗

Stroke pattern and handrim biomechanics for level and uphill wheelchair propulsion at self-selected speeds.

OBJECTIVES: To investigate the natural stroke patterns of wheelchair users pushing on a level surface, to determine if users adapt their stroke patterns for pushing uphill, and to assess whether there are biomechanic advantages to one or more of the stroke patterns. DESIGN: Case series. SETTING: Biomechanics laboratory. PARTICIPANTS: Twenty-six manual wheelchair users with a spinal cord injury. INTERVENTION: Subjects pushed their own wheelchairs at self-selected speeds on a research treadmill set to level, 3 degrees , and 6 degrees grades. Stroke patterns were measured using a motion capture system. Handrim biomechanics were measured using an instrumented wheel. MAIN OUTCOME MEASURES: Stroke patterns were classified for both level and uphill propulsion according to 1 of 4 common classifications: arcing, semi-circular, single-looping (SLOP), and double-looping (DLOP). Biomechanic outcomes of speed, peak handrim force, cadence, and push angle were all compared across stroke classifications using an analysis of variance. RESULTS: Only 3 of the 4 stroke patterns were observed. None of the subjects used the semi-circular pattern. For level propulsion, the stroke patterns were fairly balanced between arcing (42%), SLOP (31%), and DLOP (27%). Subjects tended to change their stroke pattern for pushing uphill, with 73% of the subjects choosing the arcing pattern by the 6 degrees grade. No statistically significant differences were found in handrim biomechanics or subject characteristics across stroke pattern groups. CONCLUSIONS: Wheelchair users likely adapt their stroke pattern to accommodate their propulsion environment. Based on the large percentage of subjects who adopted the arcing pattern for pushing uphill, there may be benefits to the arcing pattern for pushing uphill. In light of this and other recent work, it is recommended that clinicians not instruct users to utilize a single stroke pattern in their everyday propulsion environments.

Acceleration↗