PubMed Health⌕ Search

PubMed · 14683238

Attosecond angle-resolved photoelectron spectroscopy.

Abstract

We report experiments on the characterization of a train of attosecond pulses obtained by high-harmonic generation, using mixed-color (XUV+IR) atomic two-photon ionization and electron detection on a velocity map imaging detector. We demonstrate that the relative phase of the harmonics is encoded both in the photoelectron yield and the angular distribution as a function of XUV-IR time delay, thus making the technique suitable for the detection of single attosecond pulses. The timing of the attosecond pulse with respect to the field oscillation of the driving laser critically depends on the target gas used to generate the harmonics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S A Aseyev, Y Ni, L J Frasinski, H G Muller, M J J Vrakking. 2003-11-26. Attosecond angle-resolved photoelectron spectroscopy.. https://doi.org/10.1103/physrevlett.91.223902

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Single-molecule triplet-state photon antibunching at room temperature.

We have probed single-molecule metal-to-ligand charge transfer (MLCT) dynamics of a ruthenium complex at room temperature. Using photon antibunching measurements under continuous wave (CW) laser excitation, nonclassical photon statistics, and excitation power dependent measurements, we were able to selectively measure the single-molecule MLCT state lifetime. This work demonstrated, as the first single-molecule photon antibunching measurement of the triplet excited state, a new application of single-molecule spectroscopy on excited-state dynamics and ground-state recovering dynamics of an important class of chemical species that have often been used and studied in energy conversion and electron transfer.

Photons↗

Evaluation of a computed radiography system for megavoltage photon beam dosimetry.

Computed radiography (CR) systems have been gaining adoption as digital replacements for film for diagnostic and therapy imaging. As a result, film processors are being removed from service, leaving a void for the medical physicists who use film and processors for two-dimensional mega-voltage beam dosimetry. This is the first report to evaluate the ability of a commercial CR reader and storage phosphor plate system to accurately quantitate absolute dose and dose distributions from a 6 MV photon beam. There are potential advantages and disadvantages of current CR systems compared to film systems. CR systems inherently produce a linear dose-response over several logs of dose. However, the barium in the storage phosphor has a higher atomic number than the silver in film, resulting in significant energy sensitivity. The purpose of this work is to fully characterize the impact of these and other features of this CR system relevant to dosimetry. The tests performed and reported on in this study include uniformity of readout across a uniform field, geometrical accuracy, intra- and interday reproducibility, signal decay with time and with light exposure, dose-to-signal calibration, high dose effects, obliquity effects, perpendicular and parallel calibration results, field size and depth of measurement effects and the use of lead filters to minimize them, and intensity modulated radiation therapy quality assurance test results compared to that for film. Practical techniques are provided to optimize the accuracy of the system as a dosimetric replacement for film.

Photons↗

Surface buildup dose dependence on photon field delivery technique for IMRT.

The more complex delivery techniques required for implementation of intensity-modulated radiotherapy (IMRT) based on inverse planning optimization have changed the relationship between dose at depth and dose at buildup regions near the surface. Surface buildup dose is dependent on electron contamination primarily from the unblocked view of the flattening filter and secondarily from air and collimation systems. To evaluate the impact of beam segmentation on buildup dose, measurements were performed with 10 x 10 cm2 fields, which were delivered with 3 static 3.5 x 10 cm2 or 3 x 10 cm2 strips, 5 static 2 x 10 cm2 strips, 10 static 1 x 10 cm2 strips, and 1.1 x 10 cm2 dynamic delivery, compared with a 10 x 10 cm2 open field. Measurements were performed in water and Solid Water using parallel plate chambers, a stereotactic diode, and thermoluminescent dosimeters (TLDs) for a 6 MV X-ray beam. Depth doses at 2 mm depth (relative to dose at 10 cm depth) were lower by 6%, 7%, 11%, and 10% for the above field delivery techniques, respectively, compared to the open field. These differences are most influenced by differences in multileaf collimator (MLC) transmission contributing to the useful beam. An example IMRT field was also studied to assess variations due to delivery technique (static vs. dynamic) and intensity level. Buildup dose is weakly dependent on the multileaf delivery technique for efficient IMRT fields.

Photons↗