PubMed Health⌕ Search

PubMed · 1469342

Leg length inequality.

Abstract

OBJECTIVE: The (Pacific) Consortium for Chiropractic Research has taken the initiative to research, investigate and provide information directed toward health care accountability, including evaluation of health care measures and practices. This article is a review of the literature pertaining to leg length inequality (LLI). Leg length measures are utilized by various health care providers as an indicator of biomechanical imbalance and necessity for care. Following the overview of the incidence, classifications and clinical significance, emphasis was placed on methods of evaluation, especially the visual "quick" leg length measurement procedure. Finally, a brief section on conservative care has been provided. DATA SOURCES: The information and studies reviewed were obtained from Medline, the Index to Chiropractic Literature, Chiropractic Research Archives Collection, Physiotherapy Index, Chiropractic Literature Analysis and Retrieval System, various technique manuals, personal communication with technique research advisors, proceedings and dissertations. REFERENCE SELECTION: In spite of the widespread use of leg length measures, there is still much controversy associated with LLI, its biomechanical significance and the reliability of the various measurement systems employed. Therefore, the 182 references utilized were selected on the basis of applicable information, especially studies that provided a detailed methodological design with statistical analysis regarding evaluation procedures. CONCLUSION: There appears to be a lack of agreement concerning incidence, classification and point of clinical significance. However, the manifestations or consequences of LLI demonstrate greater accordance. Of the three most commonly utilized evaluation methods, radiographic measures such as the scanograms are recognized as the most reliable procedure for the evaluation of anatomical LLI. Much controversy exists with some of the clinical orthopedic methods and the visual "quick" leg check. Because there is such a vast range in estimates of reliability, few if any definitive conclusions can be made regarding these methods. Given this, it is evident that more research is needed before the use of certain orthopedic and visual checks are considered reliable and valid.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D M Mannello. Leg length inequality.. https://pubmed.ncbi.nlm.nih.gov/1469342/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗